DATA COLLECTION & ANALYSIS

Tag No.: A0273

Based on interview and document review there is no evidence to indicate the Pediatric Surgical Department has mechanisms in place to identify, analyze and evaluate the quality of care provided to surgical patients in a timely manner.

Findings include:

Interview on 8/17/12 at 11:15 with Staff #16 revealed each department has a department specific quality assurance program. Quality review generally consists of morbidity and mortality reviews, root cause analysis outcomes and any other concerns that are brought forth. There is no standard criterion for case review. Each specialty conducts their own review and will refer cases to other disciplines or departments for additional review as needed.


Review of the Monthly Quality Assurance Reports for Pediatric & Thoracic Surgery from December 2010 to February 2012 revealed mortality, morbidity, complaints, and utilization/antibiotic prophylaxis for acute non-perforated appendicitis are reviewed monthly.
The following issues were identified:
-No reports were found for March 2012 to August 2012.
-In October 2011 morbidity review with discussion was noted to be pending for Patient #3 and in January 2012 for Patient #2 with no further documentation regarding the outcome of the review in subsequent minutes.

Review of the Department of Pediatric Surgery Morbidity and Mortality Conference meeting minutes from 12/8/11 to 7/2/12 revealed the following case reviews:
-On 12/22/11 Patient #3 was discussed.On 10/5/11 a G-tube was placed into the colon instead of the stomach. It was identified intra-operatively and replaced into the stomach. The nature of the complication was error in judgment but a rare expected occurrence. The discussion included placement of the G-tube lap as open, use of contrast studies and co morbidities. However, no evidence was found to indicate whether the recommendations listed in the discussion were implemented or that the results of the review were reflected in the monthly Quality Assurance Report for Pediatric and Thoracic Surgery.
-On 7/5/12 Patient #2 was discussed. The patient had a laparoscopic cholecystectomy on 1/25/11 and a laparoscopic lymph node biospy on 2/8/12 with a diagnosis of lymphoma. The nature of the complication was noted to be a delay in lymphoma diagnosis. The initial diagnostic laparoscopy did not reveal the mass at the root of the mesentery. A complete review of the initial imaging did not reveal the mass. There was no evidence to indicate the case was reviewed in a timely manner or whether any quality improvement recommendations were identified.
-On 7/5/12 Patient #1 was discussed. On 9/1/11 the patient experienced bleeding after a mediport flush. An 8 ml (100u/ml) heparin flush was administered with post procedure bleeding. The nature of complication was due to error in technique and patient disease. The discussion involved a large dose of heparin flush and no documentation of the amount given intraoperatively. Quality improvement recommendations included creating a policy for heparin flush of mediport due to lack of intra-operative documentation of heparin administration. No evidence was found to indicate this case had been reviewed in a timely manner or included in the monthly Quality Assurance Report for Pediatric and Thoracic Surgery.

Review of the STARS (incident reporting system) report for facility events revealed the following cases were reported:
-Patient #21 involved a foster baby who received the same surgery twice. An investigation with interviews was conducted and a corrective action was identified. However there was no evidence to indicate how the corrective action will be monitored and evaluated.
-Patient # 22 involved a bright blood post Foley catheterization. There was no evidence found to indicate if an investigation was conducted, if the issue was resolved or if further follow up was required.

MEDICAL STAFF PERIODIC APPRAISALS

Tag No.: A0340

Based on document review and credential review, surgical privileges were not reviewed and/or updated at least every 24 months for 1 of 6 pediatric surgical staff (Staff #4).

Findings include:

Review of the Kaleida Health Bylaws of the Medical/Dental Staff dated 2/2011 revealed the following:

-The primary responsibility delegated to each clinical service is to review and evaluate the provision of patient care in order to preserve and continuously improve the quality and efficiency of patient care provided in the clinical service. Each clinical service will conduct continuing review of the clinical care and professional performance of all members of the clinical service and health professional affiliates having privileges in the clinical service.
-The chief of service is responsible for continuing surveillance of the professional performance of all individuals who have delineated clinical privileges, recommends criteria for granting clinical privileges, submits recommendations for clinical privileges for each member/applicant, continuously assesses and improves the quality of care and services provided maintaining quality control programs and provides orientation/continuing education to all person in the clinical service.
-The credentials committee duties include evaluation of the qualification of individuals applying for appointment/reappointment to the staff and privileges, integrate quality review, risk management and utilization review findings and information into the process used to evaluate appointment/reappointment applications and grant privileges, make recommendations to the Medical Executive committee to grant or deny applications.

Review on 8/20/12 of the credential file for Staff #4 revealed the following:
-No evidence of a current reappointment letter. The last reappointment letter is dated 4/9/10 and indicates reappointment from 4/7/10 to 1/31/12.
-The Kaleida Health Medical/Dental Staff Bi-Annual Performance Review report for reappointment ending 1/31/12 is blank and unsigned by the chief of service.
-Two Delineation of Privilege forms dated 9/11/11 and 2/9/12 are not signed by the chief of service. No evidence of current/approved privileges was found in the file.

Review of the email dated 8/21/12 received from Staff #1 revealed Staff #5 has not signed off on Staff # 4's reappointment and an alternate physician for credentialing sign off has not been designated.

POST-ANESTHESIA EVALUATION

Tag No.: A1005

Based on document review and medical record review the facility did not ensure a post operative anesthesia evaluation was completed for 4 of 16 patients (Patient #1, 10, 12 and 16).

Findings include:

Review of policy #SS_24 " Standard of Care and Discharge from Post Anesthesia Care Unit " last revised 9/05 revealed once discharge criteria are met, the anesthesiologist will document on the anesthesia record KH00408 and discharge the patient from Phase I post anesthesia care unit.

Review of medical records for Patient #1, 10, 12 and 16 revealed the post operative anesthesia assessment is either blank and/or incomplete.