HospitalInspections.org

Bringing transparency to federal inspections

1305 WEST 18TH STREET

SIOUX FALLS, SD null

NURSING SERVICES

Tag No.: A0385

A. Based on record review, interview, and policy review, the provider failed to ensure an order was obtained for the daily wound care provider for one of one sampled patient (3) who had drain site wounds. Findings include:

1. Record review of patient 3's electronic medical record (EMR) revealed:
*On 4/22/24 at 11:34 a.m. patient 3 had been admitted with a diagnosis of:
-Acute respiratory failure, cerebral vascular accident (CVA), aortic valve replacement, atrial fibrillation (irregular heart rhythm), deep venous thrombosis (DVT).
*On 4/22/24 at 8:24 p.m. an initial nursing assessment completed by registered nurse (RN) D revealed:
-Patient 3 had four drain site wounds to his upper abdomen.
-RN D had measured and photographed the wounds and provided wound care that had included iodoform packing to each drain site, and then covering with a silicone dressing.
--This assessment by RN D had been performed nine hours after patient 3's admission.
*On 4/23/24 at 8:00 a.m. and 8:34 p.m. documentation indicated patient 3's dressing was a non-adherent dressing.
*On 4/24/24 at 8:00 a.m. and 8:00 p.m. documentation indicated patient 3's dressing was a non-adherent dressing.
*On 4/25/24 at 7:43 a.m., 8:00 p.m., and 4/26/24 at 8:00 a.m. documentation indicated patient 3's wounds were open to air (not covered with a dressing).
*On 4/26/24 at 12:30 p.m. documentation by RN G indicated that patient 3's wounds had been measured and wound care was provided that had included iodoform packing to each drain site, and then coving the wound with a silicone dressing.
*There had not been any order for daily dressing changes for patient 3 entered in his EMR.
*On 4/30/24 patient 3 had a rapid response (a decline in a patient's health requiring specialty health services) due to his declining health status.

2. Interview on 5/22/24 at 9:00 a.m. with RN wound care nurse B regarding wound care for patient 3 revealed:
*She had received the order for his wound care evaluation on 4/29/24.
*She completed the evaluation of patient 3 on 5/1/24 and clarified the orders that had been placed on 4/26/24.
-She worked Monday through Friday and on off hours house supervisor nurses would have completed wound care.
*Patients have wound care evaluated completed within 24 hours of receiving an order.

3. Interview on 5/22/24 at 2:25 p.m. with medical doctor (MD) C regarding patient 3's history and physical including his wounds revealed:
*He did not remember receiving any information on patient 3's wounds and his wound care.
*He would have put wound care orders in the EMR system with the assistance of the wound care nurse and skin team.
*He had not documented patient 3's wounds in his history and physical.
*He had not assessed patient 3's wounds.

4. Interview on 5/22/24 at 3:34 p.m. with MD K regarding wound care revealed:
*Patient 3 had developed bacteremia and required a rapid response intervention on 4/30/24.
*He could not confirm or deny that patient 3's delay in wound care could have contributed to his rapid response on 4/30/24.
*He stated proper documentation and sign off are very important for good patient care.

5. Interview on 5/22/24 at 3:51 p.m. with RN D regarding wound care for patient 3 revealed:
*She had first assessed patient 3 on 4/22/24 on during the night shift.
*She removed his dressing and packing that he was admitted with, documented his wounds, and packed them with iodoform gauze and covered the wounds with a silicone dressing.
*RN D reviewed patient 3's orders and noticed there had not been any orders in his EMR for his wound care.
*She had passed on her wound care to the morning shift during report and then she was off work for a few days.
*If a patient had arrived after hours and on a weekend when the wound nurse was not working, house supervisors would have provided wound care until the wound nurse returned.
*She had been concerned that patient 3 had not received any wound care 4/22/24 until 4/26/24.

6. Interview on 5/23/24 at 9:00 a.m. with RN G regarding patient 3's wound care revealed:
*She had completed a dressing change to patient 3's drain sites on 4/26/24.
*She had found a transfer sheet from the sending provider with instructions for patient 3's wound care and dressing change they had provided.
*RN G had informed the hospitalist that day and received an order for daily and as needed dressing changes to patient 3's drain sites.

7. Review of the provider's July 2021 Admission of patient to the unit revealed:
*" A registered nurse will perform the initial assessment of the patient upon admission to the nursing unit and place the appropriate identification bracelets on the patient."
*" Initial assessment should be done within the first 8 hours of admission."

B. Based on observation, and interview, the provider failed to ensure maintained visualization of dialysis catheters by two of two observed contracted RN (F and H) had maintained visualization for two of two patients (7 and 8) during their dialysis treatment. Finding include:

1. Observation and interview on 5/22/24 at 10:30 a.m. with RN F during patient 7's dialysis treatment revealed:
*RN F had been sitting at a portable computer desk.
*Patient 7 had her left hand elevated on pillows.
*RN F had not been able to visualize patient 7's dialysis catheter due to patient 7 moving the pillow.
*After RN F was asked about dialysis catheter visualization, she adjusted patient 7's pillow and then asked the surveyor if that was good enough.
*She was unsure of what she needed to have constant visualization of.

2. Observation and interview on 5/22/24 at with RN H during patient 8's dialysis treatment revealed:
*Patient 8's catheter and dialysis connection sites had been covered by a part of the absorbent pad on his chest.
*RN H stated she had been able to visualize patient 8's catheter and connection site while seated at her portable computer desk.
*RN H got up from her portable computer desk and uncovered the non-visible portion of the dialysis catheter.
*She stated she had recently obtained vital signs on patient 8 and the absorbent pad had covered the catheter and connection site for only a few minutes.

3. Interview on 5/23/24 at 4:15 p.m. with director of quality management E regarding competencies (demonstration of fundamental skills) on contracted RNs revealed:
*She had only performed competencies on contracted staff for infection control practices.
*They had not received any dialysis completed competencies for the contracted nurses from the contracted service.
*Their expectation that competencies are completed annually with contracted nurses by the contracted service that provided dialysis.
*She agreed that constant visualization of catheters during dialysis was very important for patient safety.

A request for a policy for contracted dialysis had been made prior to exit. The provider did not have a policy.

INFECTION PREVENTION CONTROL ABX STEWARDSHIP

Tag No.: A0747

50715

A. Based on observation, interviews, and policy review, the provider failed to ensure two of four observed glucometers had been cleaned and disinfected properly prior to patient use. Findings include:

1. Observation on 5/21/24 at 9:30 a.m. of one glucometer docked outside of room 2475 revealed it had visible blood near the glucometer strip insertion site and on the backside of the machine.

2. Interview on 5/21/24 at 9:33 a.m. following the above observation with registered nurse (RN) D regarding the visible blood on the glucometer revealed:
*The glucometer having been in the docking station meant it had been cleaned, disinfected, and ready for patient use.
*She:
-Confirmed there was visible blood on the glucometer in the docking station.
-Agreed that it was not cleaned and disinfected prior to docking it in the station.
-Would have someone clean and disinfect it right away.

3. Observation on 5/21/24 at 11:08 a.m. at the nurse's station located in the north hallway revealed a glucometer in the docking station that had visible blood on the front, sides, and back of the machine.

Interview on 5/21/24 at 11:30 a.m. with director of quality management (DQM) E and chief nursing officer (CNO) I regarding the docked glucometers revealed:
*After use, the glucometers should have been cleaned and disinfected with a purple top disinfectant wipe per the manufacturer's recommendations and placed in the docking station.
*When the glucometers were in the docking station, they were considered by staff as cleaned, disinfected, and ready for patient use.

4. Observation on 5/22/24 at 8:22 a.m. of the same docked glucometer at the nurse's station located in the north hallway again revealed visible blood on the same areas as observed on 5/21/24 at 11:08 a.m.

5. Interview on 5/22/24 at 8:37 a.m. with DQM E regarding the above observation revealed:
*The docked glucometer should have been cleaned, disinfected, and ready for patient use.
*She agreed that the above glucometer had visible blood on it and it and required cleaning and disinfection.
*She would clean and disinfect it immediately.

6. Interview on 5/22/24 at 8:40 a.m. with RN A regarding docked glucometers revealed he stated:
*"If the glucometer is in the docking station it is clean and ready for patient use."
*"Glucometers are cleaned with a purple top wipe and the contact time is two minutes."

7. Review of the provider's October 2023 Cleaning: Environment, Patient Equipment and Medical Devices policy revealed:
*"If it is unclear where or not the equipment is clean, it must be cleaned before use.
*The standard of cleanliness is that all parts of the equipment including the underneath be visibly clean with no blood and body substances, dirt, debris, dust, adhesive tape, stains or spillage."


B. Based on observation, interviews, and monthly infection control rounding tool review, the provider failed to ensure wound care for one of one sampled patient (3) had been performed using a clean technique by one of one observed registered nurse (RN) B. Findings include:

1. Observation on 5/21/24 at 9:54 a.m. with RN B while performing wound care to patient 3 revealed she:
*Washed her hands and put on a pair of clean gloves.
*Removed the dressing and packing from four drain sites located on patient 3's abdomen.
*Removed her gloves, washed her hands, and put on a new pair of clean gloves.
*Placed dressing supplies next to the sink and the patient's clothing without a clean barrier under the wound care supplies.
*Irrigated the drain sites with normal saline and wiped them with gauze.
*Removed her gloves, washed her hands, and put on a pair of clean gloves.
*She opened a sterile Q-tip, layed it on the bedsheet, cut a string of iodoform gauze, and placed the scissors on the bedsheet.
*She then used that same Q-tip to pack one drain site with iodoform gauze.
*She repeated that same process three more times using the same technique all with those same gloved hands.
*With those same gloves she applied a silicone dressing over four drain sites, removed the gloves, and washed her hands.
*She then placed the scissors she had used in a locked drawer of a cabinets in the patient's room that contained clean supplies.
-She had not cleaned the scissors prior to placing them in that drawer.

2. Interview on 5/22/24 at 2:20 p.m. with RN B regarding a clean surface for wound care supplies revealed she:
*Stated she had wiped the surface near patient 3's sink with a purple top disinfectant wipe before setting wound care supplies down on it and prior to the surveyor arriving.
*Considered a clean workspace to be dry, not visibly dirty, and by using a clean sheet, disposable pad, or towel under the supplies.
*Considered the area by the sink to be clean workspace if it had been wiped with a purple wipe.
*Confirmed she had placed the scissors used to cut the iodoform dressing back into the drawer with other clean wound care supplies without cleaning it.
*Remembered receiving education regarding contaminated equipment must be cleaned and stored appropriately, and to designate a clean area for wound care supplies.

3. Interview on 5/22/24 at 4:13 p.m. with DQM E regarding proper handing, storage of wound care supplies, and monthly infection control rounds tool revealed she:
*Stated the patient's bed sheet would not have been considered a clean surface.
*Confirmed a disposable pad or a clean towel should have been used as a barrier.
*Would have expected the monthly infection control rounds tool as a policy.

4. Review of the provider's monthly infection control rounds tool revised June 2022 revealed, "Clean/Sterile items are not stored within 3 ft of the sink."