Tag No.: A0043

Based on interview and review of documents supplied by the hospital, the Governing Body failed to effectively carry out its responsibilities for the operations of the hospital.

1. The Governing Body failed to ensure the development, implementation, and maintenance of an effective, ongoing, hospital-wide, data-driven Quality Assessment and Performance Improvement (QAPI) program. (Refer to A-0263)

2. The Governing Body failed to ensure the development, implementation, and maintenance of an active hospital-wide program for the prevention, control, and investigation of infections and communicable diseases. (Refer to A-0747)

3. The Governing Body failed to ensure the hospital's food and dietetic services was directed and staffed by adequate qualified personnel to meet the nutritional needs of the patients in accordance with practitioners' orders and acceptable standards of practice. Failure to identify deficient food safety practices that resulted in an immediate jeopardy situation. (Cross refer A 618, A 619, A 620, A 621, A 629, A 630, A 724, A 749)

4. The Governing Body failed to ensure that the medical staff has written policies and procedures for appraisal of emergencies, initial treatment, and referral when appropriate. (Refer to A-093)

The cumulative effect of these systemic problems resulted in the Governing Body's failure to ensure provision of quality health care to patients in a safe environment.

QAPI

Tag No.: A0263

Based on interview and record review, the hospital failed to establish and maintain a hospital-wide, data-driven QAPI program to ensure quality of care and patient safety. The facility did not meet the Condition of Participation in quality assurance and performance program by failing to:

1. Establish and maintain a hospital-wide quality assurance and performance improvement (QAPI) program to ensure quality of care and patient safety. There was no ongoing program that shows measurable improvement in indicators and program data for which there is evidence that it will improve health outcomes. (Refer to A 0273 )


2. Establish and maintain a hospital-wide quality assurance and performance improvement (QAPI) program to ensure quality of care and patient safety. There was no QAPI program data for the hospital to identify opportunities for improvement and setting of priorities for its performance improvement activities. (Refer to A 0283 )

MEDICAL RECORD SERVICES

Tag No.: A0431

Based on observation, interview, and record review the facility failed to meet the Condition of Participation for Medical Record Service by failing to:

A. Ensure a patient's clinical record (Patient 15) contained an accurate description of the patient's reconciliation of personal belongings before he was discharged from the facility. (Refer to A-0438)

B. Include a completed Discharge Summary in Patient 17's clinical file; verify that the record of Patient 19 contained complete, legible, and authenticated orders. (Refer to A-0450)

C. Make sure that patients' medication orders (Patients 11-15, 17-18, 23) were promptly authenticated by the prescribing physician. (Refer to A-0454)

D. Verify that a properly executed informed consent form of Patient 31 for use of an antipsychotic medication was initiated by the prescribing practitioner. (Refer to A-0466)

The cumulative effect of these systemic problems resulted in increased probability of medication errors and/or patient safety.

FOOD AND DIETETIC SERVICES

Tag No.: A0618

Based on observation, review of facility documents, manufacturers' instruction and staff interviews, the hospital failed to ensure that the hospital was directed and staffed by adequate qualified personnel to meet the nutritional needs of the patients in accordance with practitioners' orders and acceptable standards of practice. (Cross refer A619, A620, A621, A629, A630, A724, A749)

1. Failure to organize the food and nutrition services in a manner to meet the needs of the patients and appropriate to the scope and complexity of the service operations. (Cross refer A 619)

2. The person in the position of the director of food and nutrition services department who did not meet the educational requirements and training that met state law. (Cross refer A 620)

3. Failure to identify deficient food safety practices that resulted in an immediate jeopardy situation. (Cross refer A 620 and A 749)

4. Lack of a system to incorporate the services and expertise of a registered dietitian in the nutrition care of patients. (Cross refer A 620)

5. Inadequate provision of dietitian hours and consultation services that met the needs of the patients. (Cross refer A 621)

6. Failure to provide adequate registered dietitian coverage to meet the needs of the patients. (Cross refer A 621)

7. Failure to collaborate with nursing services and other services to plan and implement patient care as necessary to meet the nutritional needs of the patients. (Cross refer A 621)

8. Lack of menu that meets the nutritional needs of the patients. (Cross refer A 629)

9. Failure to approve and analyze patient menus. (Cross refer A 629)

10. Lack of an effective system to evaluate the nutritional needs of patients that includes follow-up assessment of patients, current professional standards.( Cross refer A 630)

11. Failure to perform and document nutrition assessments according to current standards of practice. (Cross refer A621 and A630)

12. Lack of implementation of a system that ensures the proper food safety practices. (Cross refer A 749)

13. Lack of maintenance of food service equipment. (Cross refer A 724)

14. Failure to provide oversight of the food service operation and its director of food services who did not meet state educational requirements for the position. (Cross refer A 749)

15. Lack of a data driven quality assurance, performance improvement program. (Cross refer A 297)

The cumulative effect of these systemic problems resulted in the inability of the hospital's food and nutrition services to direct and staff in such a manner to ensure that the nutritional needs of the patients were met in accordance with practitioners' orders and acceptable standards of professional practice. Therefore, the Condition of Participation for Food and Dietetic Services was not met.

PHYSICAL ENVIRONMENT

Tag No.: A0700

Based on observation, interview and document review it was determined that the facility did not meet the Condition of Participation (COP) for Physical Environment by failing to:

1. Maintain In Patient accessible areas free of fixtures that were not of anti-ligature design or anti-ligature protected, that could be used as anchor points to tie to and that can hold a person's weight. (Refer to A 701)

2. Maintain a bathroom sink fixture as to not have and exposed water valve stem. (Refer to A 701)

3. Maintain a patient room corridor door secured firmly to its door frame assembly. (Refer to A 701)

4. Maintain patient room wall finishes to be easily cleaned and disinfected. (Refer to A 701)

5. Maintain a food storage room free of accumulation of dust. (Refer to A 701)

6. Maintain a food storage and preparation area free of chemicals and material that could adulterate food. (Refer to A 701)

7. Maintain a dishwashing area wall clean and free of accumulation of black material growth. (Refer to A 701)

8. Maintain ceiling tiles free of water damage. (Refer to A 701)

9. Maintain posted warning signage of water that is 120 oF (degrees Fahrenheit) or higher. (Refer to A 701)

10. Provide documented evidence of an assessment conducted to determine the quantity of emergency water needed by the facility. (Refer to A 703)

11. Maintain a sight glass of the fuel gauge at the emergency generator's day tank so that the fuel level in the tank could be read. (Refer to A 709)

12. Maintain the main electrical panel room free of storage. (Refer to A 709)

13. Maintain the main electrical panel room and boiler room walls free of penetrations. (Refer to A 709)

14. Maintain the storage room corridor door free of penetration. (Refer to A 709)

15. Maintain the Information Technology (IT) server room ceiling free of penetrations. (Refer to A 709)

16. Maintain smoke and fire barriers free of penetrations. (Refer to A 709)

17. Maintain patient room walls of combustible or limited combustible construction. (Refer to A 709)

18. Maintain exit doors unobstructed. (Refer to A 709)

19. Ensure corridor doors can hold closed when shut. (Refer to A 709)

20. Maintain a corridor door in place. (Refer to A 709)

21. Maintain an astragal at corridor Dutch door. (Refer to A 709)

22. Maintain exit signage and exit directional signage available and unobstructed from view, from any part of the occupied area. (Refer to A 709)

23. Maintain fire extinguisher and hose in corridor cabinet readily accessible by maintaining a handle at the cabinet door. (Refer to A 709)

24. Maintain fire extinguisher properly hung as to not damage hose. (Refer to A 709)

25. Maintain an 18 inch clearance between the bottom of a sprinkler head deflector and the top of storage. (Refer to A 709)

26. Maintain electrical cover plate free of damage. (Refer to A 709)

27. Maintain Kitchen suppression system blow off caps in place. (Refer to A 709)

28. Maintain an oxygen cylinders secured, separate empty from full and identified by posted signage. (Refer to A 709)

29. Correctly use extension cords including power strips. (Refer to A 709)

30. Maintain documented evidence of inspection and testing of drop down fire doors, and rating plates legible. (Refer to A 709)

31. Maintain documented evidence of sensitivity of the smoke detectors. (Refer to A 709)

32. Maintain documented evidence that the transfer switch was being inspected and tested. (Refer to A 709)

33. Maintain documented that transfer time of emergency power was being tested. (Refer to A 709)

34. Maintain documented evidence that smoking regulations were adopted for smoking by patients. (Refer to A 709)

35. Ensure facilities and food service equipment were maintained to an acceptable level of safety for patients and staff; ensure the water faucet was working in the handwashing sink located inside the medication storage area at the children inpatient nursing unit (CIP). (Refer to A 724)

36. Maintain eyewashes in a condition to provide quick drenching or flushing of the eyes with water delivered at a tepid temperature. (Refer to A 724)

37. Maintain documented evidence of testing of the eyewash stations. (Refer to A 724)

38. Maintain light fixtures diffusers/covers and light shields in good repair and in place. (Refer to A 724)

39. Maintain ceiling light fixtures to provide light at kitchen working areas. (Refer to A 726)

40. Maintain light in food storage refrigerator freezer. (Refer to A 726)

41. Monitor temperatures in all pharmaceutical storage areas with instrumentation that has the range to determine if the ambient room temperature is out of range. (Refer to A 726)

The cumulative effect of these systemic problems resulted in the Facility's inability to ensure the provision of quality health care in a safe and sanitary environment.

INFECTION PREVENTION CONTROL ABX STEWARDSHIP

Tag No.: A0747

Bases on observation, interview and record review the hospital did not meet the Condition of Participation in Infection control by failing to:

1. Designate a qualified infection control officer verified by experience, training, education, or certification. (Refer to A 0748)

2. Develop a system to prevent infections when it failed to monitor the cooling of several leftover or over-produced time temperature control for safety (TCS) food items (formerly potentially hazardous food). The facility did not have a system in place to ensure food was cooled to the appropriate temperature within the recommended time-frames. (Refer to A 749)

3. Monitor temperatures or utilize a cooling log to document the process. (Refer to A 749)

4. Ensure the director of the food service operation meet state educational requirements for the job including completion of a food safety course for managers. Only two of the ten employees had completed a food safety course contrary to state law that requires all food service works to complete a food handler's course. (Refer to A 749)

5. Provide a hospital wide infection control plan. (Refer to A 749)

6. Provide a safe and sanitary environment for patients, by failing to ensure the glucometer (a machine that checks the amount of sugar in the blood stream) was disinfected according to manufacturer's instructions. (Refer to A 749)

The cumulative effect of these systemic problems resulted in the facility's inability to provide an effective hospital wide infection control program in a safe manner leading to increase probability of spread of infection.

SPECIAL MEDICAL RECORD REQUIREMENTS

Tag No.: B0103

Based on record review and interview, the facility failed to:

I. Ensure the psychosocial assessments include the conclusions and recommendations related to the anticipated social work role(s) in treatment and discharge planning for eight (8) out of eight (8) active sample patients (1, 2, 3, 4, 5, 6, 7, and 8) did not have the anticipated role(s) of the social worker. As a result, critical and professional patient psychosocial information necessary for informed treatment planning decisions was not available. (Refer to B108)

II. Ensure that Psychiatric Evaluations:

A. Were performed in a timely manner for two (2) of two (2) discharged patients (N1 and N2) added to review a critical incident. There were no psychiatric assessments completed on these patients prior to their discharge from the facility. This failure delays the treatment of acute symptoms with psychotropic medications and professional therapies. (Refer to B110)

B. Included an estimation of patients' memory with supporting clinical evidence for six (6) of eight (8) active sample patients This deficiency compromises the database from which diagnoses are determined and from which changes in response to treatment interventions may be measured. (Refer to B110)

III. Provide adequate treatment and monitoring for one (1) of three (3) discharged patients (N1) who subsequently assaulted and murdered his/her roommate (E1). In addition, the facility failed to ensure that an adequate root cause analysis and a prompt review by their Morbidity and Mortality Board of the circumstances surrounding this event were completed to implement corrective actions. Without taking appropriate and immediate actions to mitigate risks and prevent future recurrence of these unsafe practices, the health and safety of all newly admitted patients may be jeopardized. (Refer to B125)

IV. Ensure the discharge summaries are completed in a timely manner and signed by the physician within 14 days of discharge for three (3) of five (5) discharged patients (D1, D3, and D4) and for three (3) of three (3) added patients to review summaries (N1, N2, and E1). This deficiency results in a failure to communicate in a timely manner final diagnosis, current medications, the course of treatment, a summary of relevant labs and testing, anticipated problems and discharge plan with outpatient providers. (Refer to B133)

EMERGENCY SERVICES

Tag No.: A0091

Based on observations, interview, and record review, the facility failed to ensure patient safety and well-being, by failing to:

1. Ensure staff on Adult Inpatient Unit (AIP) 1 and AIP 2 were aware of a change in the emergency equipment, which had the potential to result in delayed emergency response for patients.

2. Ensure the maintenance date had not expired for one of two oxygen (O2) tanks on AIP Unit 2, and that the tanks were easily accessible, in order to prevent delay in treatment in the event of an emergency, and ensure biomedical maintenance was conducted prior to the expiration dates for two out of two O2 tanks on the Children's Inpatient Unit (CIP).

3. Ensure staff on the CIP Unit were checking the Emergency Cart on a regular basis, in order to prevent inadequate supply of supplies and equipment in the event of a medical emergency.

Findings:

1. On 8/3/18 at 11 a.m. on Adult Inpatient Unit (AIP) 2, when RN7 was asked the location of the Emergency Cart, he pointed to an area behind the desk in the Nurses Station, and stated the cart was supposed to be there, then stated the pharmacy staff may have taken the cart in order to restock it. Several other staff members also stated the Emergency Cart was kept in the Nurses Station. RN 1 then obtained a plastic orange box from AIP Unit 1 that contained an Ambu Bag, stethoscope, and blood pressure cuff and stated the Emergency Cart had been replaced by the box several months ago because it was easier to take to an emergency.

2. On 8/3/18 at 11 a.m. on Adult Inpatient Unit (AIP) 2, two O2 tanks were observed in the Valuables Closet, which was kept locked. The Chief Nursing Officer (CNO) stated the tanks were supposed to be located against the wall of the Nurses Station and not locked up, in order to be accessible in the event of an emergency.

3. On 8/3/18 at 9:35 a.m., during an observation of the Treatment Room on Children's Inpatient Unit with RN 5, a review of the Signature Sheet on the Emergency Cart indicated the emergency medications were checked on a daily basis, however, there was no indication that the supplies in the cart were also being checked. RN 5 stated the cart should be checked every day.

Two out of two O2 tanks in the Treatment Room had expired maintenance dates. RN 5 acknowledged the dates had expired, and that he would inform the Maintenance Department.

EMERGENCY SERVICES

Tag No.: A0093

Based on interview and review of documents supplied by the hospital, the hospital medical staff failed to adopt written policies and procedures for the management of medical emergencies, including appraisal, initial treatment, referral and transportation of individuals with emergencies.

Findings:

Interview conducted on 8/2/18 at 1400 hours with the Medical Director. When asked about the hospital's policy for handling persons with medical emergencies, the Medical Director stated that a physician is always on-call and all medical staff are certified in Basic Life Support (BLS). If medical staff are present on-site, they will directly participate in emergency care, whereas during after-hours when only on-call coverage is available, the nurses call the on-call physician for direction. He added that if the on-call physician cannot be reached immediately, he usually serves as backup and the nurses can call him.

Interview conducted on 8/3/18 at 0955 hours with the Charge Nurse for Adult Inpatient Unit 1 (RN 1), in presence of another registered nurse on duty (RN2). When questioned about how they address and care for persons in emergency conditions, RN1 stated she would first assess the individual, stabilize, notify the physician on duty or on-call, and if needed, call 911 and transfer the individual to an acute care hospital. She added all nursing staff are BLS-certified and trained to perform CPR. RN2 agreed with the stated protocol.

The Medical Staff Bylaws Section 7.5 Emergency and/or Disaster Privileges, dated October 2014, reads:
"(a) In the case of an emergency, any Physician, to the degree permitted by his or her license and regardless of department, staff status, or Clinical Privileges, shall be permitted to do everything reasonably possible to save the life of a patient or to save a patient from serious harm. The physician shall make every reasonable effort to communicate promptly with the Medical Director concerning the need for emergency care and assistance by Members of the Medical Staff with appropriate Clinical Privileges, and once the emergency has passed or assistance has been made available, shall defer to the Medical Director with respect to further care of the patient at the Hospital."
"(b) In the event of an emergency, any non-Physician shall be permitted to do whatever is reasonably possible to save the life of a patient or to save a patient from serious harm. Such non-Physicians shall promptly yield such care to qualified Members of the Medical Staff or other Physician when he or she becomes available.

On 8/2/18 at 1530 hours [3:30 p.m.], when requested to provide a written policy and procedure on hospital's management of medical emergencies, the Director of Quality Management stated she was unsure whether a written policy was available but she would look for it. Subsequently, she indicated she did not identify any such document.

PATIENT RIGHTS: NOTICE OF RIGHTS

Tag No.: A0117

Based on observation and interview, the facility failed to display the correct phone number and address of the State agency responsible for receiving reports of complaints as per regulation. The facility also failed to ensure the legal guardian of an underage patient received and acknowledged the patient's rights and related documents.

Findings:

1. Upon entering the facility on 7/31/2018 at 8:20 AM, it was noted that the information located on the wall in the reception area of the lobby for addressing complaints was only for the Department of Mental Health; no address was listed for the California Department of Public Health.

At that time, the Director of Nursing Primary Care (DONPC) stated she did not know the correct address; she was given the correct address and phone number to which to report complaints regarding patient care; she stated the appropriate changes would be forthcoming.


28851


2. Review of Patient 15's admission record indicated the patient was eight years old when admitted.

On 8/2/2018 at 11:25 a.m., during an interview and concurrent review of patient medical records, the director of quality management confirmed the signatures on the "Rights of Patients" and Acknowledgement of Receipts: Notice of Privacy Practices". The director indicated hospital staff should inform and obtain signature from the legal guardian of an underage patient.

PATIENT RIGHTS: INFORMED CONSENT

Tag No.: A0131

Based on record review and interview, the facility failed to inform the patient (Patient 3) of a proposed antipsychotic medication (those in a class of psychiatric drugs used to treat major illnesses such as schizophrenia and bipolar disorder. They work to reduce delusional thought, hallucinations, and physical/emotional overactivity) thus decreasing the patient's involvement in his plan of care.

Findings:

During a record review of Patient 3's file, the "[Facility Name] Consent to receive psychotropic medications" indicated the patient had consented (agreed to treatment) on 6/22/18 to take the following medications: Latuda (antipsychotic medication used to treat schizophrenia and bipolar disorder), Ativan (typically used to treat anxiety and sleeplessness), Restoril (used for insomnia or panic disorder). There was no evidence of consent for the medication Seroquel.

A review of physician orders for Patient 3 showed an order was written on 6/22/18 for Seroquel 100 milligrams (mg) by mouth (PO) at bedtime (qhs).

The Medication Administration Record (MAR) for this patient on 6/22/18 revealed that he had been given Seroquel 100 mg PO at 21:00 on 6/22/18.

In a brief discussion with the Charge Nurse on 8/1/18 at 9:00 AM, he attested that the medication Seroquel should have been listed on the patient's consent to treat form.

According to [Facility Name] Policy and Procedure "Informed Consent to Antipsychotic Medications", a voluntary patient shall give consent to receive psychotropic medications only after being informed of the patient's right to accept or refuse treatment with the proposed medication as well as the benefits and side effects of the medication.

PATIENT RIGHTS: CARE IN SAFE SETTING

Tag No.: A0144

Based on observation, interview, and record review, the facility failed to ensure a safe environment is provided for patients, by failing to:

1. Ensure the facility was free from ligature risk (anything which could be used to attach a cord, rope, or other material for the purpose of hanging or strangulation) in patient care areas, which had the potential to result in patient self- harm or death.

2. Ensure incident reports and investigations of the reports were completed, and ensure there was coordination of the reports by Security Staff and facility staff. This failure had the potential to result in incomplete investigations of adverse events.

Findings:

1. On 8/3/18 at 9:25 a.m., an observation of the Employee Bathroom in the Children's Inpatient Unit (CIP), located across from the Nurses Station, revealed a drain pipe on the toilet, and a U-pipe on the sink. The door was partially open, and did not have a security lock.

When questioned, RN 5 stated there was always a staff member in the Nurses Station who would be able to monitor the restroom.

On 8/3/18 at 9:40 a.m., an observation of the Adult Outpatient Male and Female Rest Rooms also indicated there were regular drain pipes on the toilets and sinks.

On 8/3/18 at 3:20 p.m., during an interview with the Safety Director, he stated he was not aware of the ligature in the restrooms, and that the facility did not have a policy that addressed ligature risk.

2. On 8/1/18, a review of Reports provided by the facility indicated the reports were being submitted by both Security Staff and the facility staff. Some of the reports were not completely filled out, and did not indicate investigation outcomes.

a) A Report, dated 7/2/18, and completed by a Case Manager, indicated Patient 43 (on the Children's Inpatient Unit) had alleged that a mental health worker (MHW) had choked him. The patient's room number, age, reason for hospitalization, time the Case Manager was notified, and whether the patient was seen by a physician, had been left blank. The report indicated the patient's physician was notified. However there was no further information regarding whether the alleged perpetrator was interviewed, or the final outcome of the investigation.

b) A Report dated 6/28/18 and completed by a registered nurse (RN), indicated Patient 44's family member had called and stated that Patient 44 had told him she had been sexually assaulted by her roommate. The family member also stated that he had called the prior night and had spoken to another staff member regarding his concern for Patient 44's safety. The report further indicated that the family member expressed concern for Patient 44's safety to the RN, and requested that she be transferred to another room. Further review of the incident report indicated that the RN had assured the family member that the patient was safe, and would report the family member's concerns to the supervisor. The section of the report that addressed whether the physician was notified, and whether the patient was seen by a physician, were both checked "No." The signature of the RN who completed the report was illegible.
There was no indication of further investigation by the facility.

On 8/1/18 at 10:45 a.m., during an interview, the Director of Quality Assurance (QA) was asked regarding how reports were handled. The Director stated she has been at the facility just over a month, and that there was no one in the position for the prior year. She also stated that there is no Patient Safety Manager or a Risk Manager. The QA Director then stated she has been trying to implement a method for handling the reports she receives from security staff and floor staff, and was not sure if the reports had been investigated yet. She added that there was no system to indicate whether the reports were still open, or if they had already been investigated.

PATIENT RIGHTS: RESTRAINT OR SECLUSION

Tag No.: A0175

Based on interview and record review, the facility failed to follow accepted practice with regard to monitoring patients who were under restraint. Assessment and monitoring should be performed to prevent injury to the patient and ensure the restraint can be discontinued as soon as possible.

Findings:

According to an "Emergency Psychoactive Medication Physician Order Form" completed for Patient 21 on 7/29/18 at 06:20, the following medications were ordered and validated by the physician on 7/29/18: Haldol, Benadryl, Ativan; each medication was to be given one time for signs of agitation.

The "Emergency Use of Medications Assessment Flowsheet" asserts that the patient should be monitored and monitoring documented every 15 minutes after administration of restraint. There was no apparent documentation for this incident in the patient's file.

During a short conversation with the Charge Nurse on 8/2/18 at 11:40 AM, he acknowledged that there should be documentation of this monitoring.

A review of the facility's policy and procedure titled, "Seclusion and Restraint Use" (page 5 of 7) stipulated that a licensed staff member who is trained and competent in the use of restraints must assess the patient at the initiation of the restraint use and every 15 minutes thereafter in order to assess the needs and physical condition of the patient during this time.

DATA COLLECTION & ANALYSIS

Tag No.: A0273

Based on interview and record review, the hospital failed to establish and maintain a hospital-wide quality assurance and performance improvement (QAPI) program to ensure quality of care and patient safety. There was no ongoing program that shows measurable improvement in indicators and program data for which there is evidence that it will improve health outcomes.

Findings:

An interview was conducted on 8/2/18 at 3:50 p.m., with the Director of Quality Management. When requested to provide the minutes of the QAPI Committee, the Director of Quality Management was unable to produce the documents, stating that the committee does not yet exist. She reported that her position had remained vacant since the previous director left about two years ago, and no definable QAPI program was in place at the hospital when she first arrived just over a month ago. She added that she has recently developed a QAPI plan, and has begun the process of training the staff in each department on determining quality indicators and gathering data. The Director subsequently furnished a document titled, "[Facility name] Health QAPI Program - Resource Guide" dated 7/5/18. Review of the document indicated an outline that defines the structure and components of the QAPI program in general.

QUALITY IMPROVEMENT ACTIVITIES

Tag No.: A0283

Based on interview and record review, the hospital failed to establish and maintain a hospital-wide quality assurance and performance improvement (QAPI) program to ensure quality of care and patient safety. There was no QAPI program data for the hospital to identify opportunities for improvement and setting of priorities for its performance improvement activities.

Findings:

Interview conducted on 8/2/18 at 1530 hours with the Director of Quality Management. When requested to provide the minutes of the QAPI Committee, the Director of Quality Management was unable to produce the documents, stating that the committee does not yet exist. She reported that her position had remained vacant since the previous director left about two years ago, and no definable QAPI program was in place at the hospital when she first arrived just over a month ago. She added that she has recently developed a QAPI plan, and has begun the process of training the staff in each department on determining quality indicators and gathering data. The Director subsequently furnished a document titled "[Facility Name] Health QAPI Program - Resource Guide" dated 7/5/18. Review of the document indicated an outline that defines the structure and components of the QAPI program in general.

QAPI PERFORMANCE IMPROVEMENT PROJECTS

Tag No.: A0297

Based on interview and record review, the hospital as part of its quality assessment and performance improvement (QAPI) program failed to have documentation what quality improvement projects are being conducted to ensure quality of care and patient safety. There were no QAPI projects for review.

Findings:

An interview was conducted on 8/2/18 at 15:30 p.m. with the Director of Quality Management. When requested to provide the minutes of the QAPI Committee, the Director of Quality Management was unable to produce the documents, stating that the committee does not yet exist. She reported that her position had remained vacant since the previous director left about two years ago, and no definable QAPI program was in place at the hospital when she first arrived just over a month ago. She added that she has recently developed a QAPI plan, and has begun the process of training the staff in each department on determining quality indicators and gathering data. The Director subsequently furnished a document titled "[Facility Name] Health QAPI Program - Resource Guide" dated 7/5/18. Review of the document indicated an outline that defines the structure and components of the QAPI program in general.

In the interview on August 3, 2018 starting at 9:12 AM, both registered dietitians (RD1 and RD2) indicated they currently do not have any performance improvement projects going on and did not develop any in the past. RD 1 stated her monthly audits are presented to the administrator and director of food services. A review of the facility document titled "Sanitation Report" completed monthly by RD 1 from November 2017 through April 2018 showed poor labeling as one of the identified concerns. Most of the other deficient practices identified during the survey were however, not identified by RD 1.

RN SUPERVISION OF NURSING CARE

Tag No.: A0395

Based on record review and interview, the hospital failed to ensure a registered nurse would assess each patient on admission to develop and implement appropriate care plan that meet the patient's need (Patient 31).

Findings:

Review of Patient 31's admission record indicated Patient 31 was admitted on 7/23/2018 and was transferred from another general acute care hospital (GACH). Review of a laboratory report from the previous GACH indicated that on 7/22/2018, a day before this hospital admission, Patient 31 had skin rash confirmed to be scabies (a contagious skin condition caused by an infestation of mites).

On 8/3/2018 at around 2:10 p.m. during a concurrent interview with the chief of nursing (CON), CON confirmed that Patient 31's physician orders and interdisciplinary plan of care did not indicate an assessment nor a treatment plan for Patient 31's contagious skin condition.

FORM AND RETENTION OF RECORDS

Tag No.: A0438

Based on observation, interview, and record review, the hospital failed to ensure patient's medical record was accurately written (Patient 15).

Findings:

On 8/1/2018 at around 4 p.m. during an inspection of the hospital's night locker (a medication storage area designated for after-hour access, after the pharmacy is closed) in the presence of the director of pharmacy (DOP), there were two drawers with signage indicating the drawers may contain patients' own medications or medication brought from home upon admission. Inside one of those drawers, there was a sealed paper bag marked with Patient 15's name.

Review of Patient 15's medical record indicated Patient 15 had been discharged on 7/17/2018. Review of Patient 15's Interdisciplinary Discharge Summary dated 7/17/2018 at 4:05 p.m. revealed an entry by a registered nurse stating "Patient discharged with all personal belongings."

(Cross reference A 500)

MEDICAL RECORD SERVICES

Tag No.: A0450

Based on interview and record review, the facility failed to make certain that patient's medical record (Patient 19) contained complete, legible, and authenticated orders. The hospital also failed to ensure Patient 17's Interdisciplinary Discharge Summary was completed.

Findings:

1. During a record review of Patient 19's file, physician admission orders were taken by telephone by a registered nurse and written 6/21/18 at 7:25 PM. The admitting diagnosis for this patient was unspecified psychosis. Among the medications ordered upon admission were the following: Ativan (medication typically used to control anxiety or sleeplessness), Restoril (used to treat sleeplessness), and Geodon (atypical antipsychotic medication that treats schizophrenia and bipolar disorder. There was no documentation showing the ordering physician authenticated these orders.

A subsequent order for this same patient on 6/21/18 at 7:58 PM indicated that an order for open seclusion along with cuffs/anklets restraints were to begin 6/21/18 at 7:50 PM and end 6/21/18 at 11:50 PM. There was no indication that the ordering physician had signed the orders.

During a brief conversation with the Charge Nurse on 8/2/18 at 1205 PM, he stated that the orders should have been signed within 48 hours of the origination of the order.

According to the "[Facility Name] Policies and Procedures - Medication Administration", telephone or verbal orders are to be written only by authorized personnel for emergency situations; such orders should be documented in the patient's progress notes and these orders countersigned by the ordering physician within two (2) working days.


28851


2. During a review of closed records, Patient 17's Interdisciplinary Discharge Summary (paper form) was blank.

On 8/3/2018 around 2:10 p.m., the Chief of Nursing (CON) presented a printout of the electronic version of the aforementioned form which indicated two of six disciplinary services; nursing and rehabilitation services, had made an entry each. However, the other four services were blank, including psychiatric, psychological, and social services.

During a concurrent interview, the CON indicated the interdisciplinary discharge summary should have been completed prior to the patient's discharge. Patient 17 was discharged on 7/26/2018.

CONTENT OF RECORD: ORDERS DATED & SIGNED

Tag No.: A0454

Based on interviews and record reviews, the hospital failed to ensure medication orders were authenticated and/or signed by the prescribing practitioner promptly (Patients 11, 12, 13, 14, 15, 17, 18, 23, 9, 10, 35 and 36). This deficient practice had a potential for medication errors and/or patient safety.

Findings:

1. Review of Patient 11's physician admission order dated 7/27/2018 at 6:20 a.m. indicated it was a telephone order and the prescriber had not authenticated the order as of 8/1/2018.

2. Review of Patient 12's physician admission order dated 7/21/2018 at 6:42 p.m. indicated it was a telephone order and the prescriber had not authenticated the order as of 8/1/2018.

3. Review of Patient 13's physician admission order dated 6/24/2018 at 6:30 p.m. indicated it was a telephone order and the prescriber had not authenticated the order as of 8/1/2018.

4. Review of Patient 14's physician admission order dated 6/12/2018 at 8:35 p.m. indicated it was a telephone order and the prescriber had not authenticated the order as of 8/1/2018.

5. Review of Patient 15's physician admission order dated 7/6/2018 at 8:10 p.m. indicated it was a telephone order and the prescriber had not authenticated the order as of 8/1/2018. Patient 15 was discharged on 7/17/2018.

6. Review of Patient 17's physician admission order dated 7/19/2018 at 1:00 a.m. indicated it was a telephone order and the prescriber had not authenticated the order as of 8/1/2018.

7. Review of Patient 18's physician admission order dated 7/19/2018 at 9:30 p.m. indicated it was a telephone order and the prescriber had not authenticated the order as of 8/1/2018.

8. Review of Patient 23's physician admission order dated 7/22/2018 at 6:55 p.m. indicated it was a telephone order and the prescriber had not authenticated the order as of 8/1/2018.

On 8/2/2018 at 9:40 a.m. during an interview, the chief of nursing (CON) indicated the prescribers should sign the orders within 24-48 hours.

Review of the hospital policy and procedure, Verbal/Telephone Orders, last reviewed in 4/2018, indicated " ...Orders that are not written by a prescriber (e.g., verbal or telephone) shall be subsequently authenticated (verified) and countersigned by the prescribing practitioner ... within 48 hours. The prescribing practitioner must enter signature, date, and time authenticating the order."



39890

9. Review of of the closed record for Patient 9 indicated a telephone order for lice-killing shampoo, dictated on 6/20/18 at 1800 [6 p.m.], was signed by the physician but not dated and timed.

In the physician's orders for Lithium and Zyprexa, written on 6/21/18 at 1658 [4:58 p.m.], route of administration was omitted.

Informed consent for treatment with psychotropic drugs was not completed.

10. Review of the closed record for Patient 10 indicated a telephone order for Haldol, Ativan, and Benadryl, dictated on 6/17/18 at 1000 hours, was signed and dated by the physician but not timed.

Physician's telephone order to discharge the patient, dictated on 6/22/18 at 0900 hours, was not authenticated.

Emergency psychoactive medication physician order, dictated on 6/17/18 at 1030 hours, was not authenticated.

11. Review of Patient 35's medical record on 8/3/18 indicated a telephone order for renewal of Ativan and Restoril, dictated on 8/1/18 at 0800 hours, was signed by the physician but not dated and timed.

Physician telephone order for renewal of Ativan and Restoril, dictated on 7/25/18 at 0800 hours, was not authenticated.

12. review of Patient 36's medical record indicated a telephone order for Ensure, dictated on 7/30/18 at 1915 [7:15 p.m.], was not authenticated.

Physician Admission Orders, dictated on 7/27/18 at 1715 hours, were not authenticated.

According to the Medical Staff "Rules and Regulations, Section 6.5 Clinician Orders", dated October 2014, "Orders dictated over the telephone shall be signed by the person to whom dictated per the name of the Clinician, indicating the time and date the order was given. Telephone orders for medications, restraints and seclusion must be signed by the attending psychiatrist or consulting physician, as appropriate, within 24 hours, all other telephone orders must be signed within 48 hours."

CONTENT OF RECORD: INFORMED CONSENT

Tag No.: A0466

Based on interviews and record reviews, the hospital failed to ensure prescribing practitioner complete an informed consent for the use of an antipsychotic medication on Patient 31.

Findings:

Review of Patient 31's physician's orders indicated an order of Invega Sustenna (a long-acting antipsychotic medication indicated for the treatment of psychiatric conditions) 234 milligrams intramuscularly (into the muscle). This order was dated on 8/1/2018 at 11:30 a.m.

Review of Patient 31's Medication Consent for Atypical Long-Acting Anti-Psychotics form, dated 8/1/2018, did not include the medication name and dosage.

On 8/3/2018 at 2:10 p.m. during a concurrent interview, the chief of nursing confirmed the antipsychotic consent should be filled out completely with the name and dosage of the medication prescribed.

DELIVERY OF DRUGS

Tag No.: A0500

Based on observation, interview, and record reviews, the hospital failed to:

1. Ensure the pharmacy and therapeutics committee (P&T, a committee that would be responsible for the establishment and evaluation of a safe and effective system in the use of medications and chemicals) would be held as per policy.

2. Ensure its policy and procedure accurately described the current process of medication dispensing.

3. Ensure discharged medication dispensed by a retail pharmacy would be returned if the patients were not discharged within seven days.

4. Ensure patient's own/home medications be returned to the patient on discharge.

Findings:

1. On 7/31/2018 at 12:55 p.m. during an interview, and a concurrent review of the hospital's P&T committee records for the past twelve months, the director of pharmacy (DOP) confirmed the committee had met twice in the year of 2017 (on 3/24/2017 and 11/15/2017) and once thus far in 2018 (on 4/13/2018). The P&T records consisted of the agendas and exhibits presented at the meetings; however, the attendances and minutes for these past meetings were not readily available.

Review of the hospital policy and procedure, Pharmacy and Therapeutics Committee, last reviewed in 4/2018, indicated "The Pharmacy and Therapeutics Committee exists as part of the Hospital Medical Staff. It is an advisory group of the medical staff ... The committee shall consist of at least three physicians, ... one pharmacist, the director of nursing service ..., medical staff secretary, and the administrator ... The recording of the meeting's minutes shall be the responsibility of the Medical Staff secretary and shall be maintained in the permanent records of the hospital. The committee shall meet at regular intervals, no less frequently than quarterly or four times per year ..."

2. On 7/31/2018 at 12:40 PM, during an interview, the director of pharmacy (DOP) stated the pharmacy hours were Mondays through Fridays from 9 am to 7 PM. The hospital had a night locker (a medication storage area designated for after-hour access, after the pharmacy is closed) and maintained floor stock at each nursing unit.

On 8/1/2018 at around 4:30 PM, during an interview, the DOP stated the nursing usage logs of the after-hour night locker would be reviewed every Friday.

Review of the hospital's After Hours Medication Room (night locker) Dispensing Log for the months of June and July in 2018 indicated there were at least thirty doses removed during the pharmacy hours.

On 8/2/2018 at around 4 PM, during an interview, and concurrent review of the night locker dispensing log, the DOP acknowledged there were multiple doses removed by a licensed vocational nurses (LVN) and entries written in types of ink and/or penmanship different than the nurses' names. The DOP stated only a registered nurse should access and document medications removed from the night locker. The DOP also confirmed there were multiple doses removed during pharmacy hours, and many doses removed at the same time for multiple patients. The DOP acknowledged most of these doses were removed shortly before or after pharmacy hours. The DOP further confirmed the access to the night locker should be limited to after hours and for immediate use; there were overlapped medication storage in the floor stock and the night locker.

Review of the hospital policy and procedure, After Hour Dispensing, last reviewed in 4/2018, indicated " ... The hospital shall established a supply of medications which is accessible without entering the pharmacy during hours when the pharmacist is not available. Access to the supplies shall be limited to designated registered nurses ... When medications are ordered for patients after pharmacy hours, the designated registered nurse should ... obtain the necessary medications from the after-hours medication room ... for the [patients'] immediate needs. The pharmacist shall reconcile all items removed from the After Hours Medication Room the next day to the physician's orders."

Review of another hospital policy and procedure, Dispensing General, last reviewed in 4/2018, indicated " ... If the order is written when the pharmacy is "closed" ... it should be reviewed by a pharmacist as soon thereafter as possible, preferably within 24 hours, but not more than 72 hours following preparation and dispensing ..."

3. On 7/31/2018 at 2:45 PM during an inspection of the medication room at the Adult Inpatient nursing unit 1 (AIP-1), there were at least seven brown paper bags in a cabinet; each bag was individually labeled for different patients. Two of those bags (labeled for Patient 13 and 14 respectively) were dated at least ten days to a month prior. The labels on those brown bags indicated it was from a pharmacy named differently than the hospital.

During a concurrent interview, the director of pharmacy (DOP) indicated those bags contained discharge medications dispensed by a retail pharmacy located within the hospital premises as a separate entity (not listed on the hospital license). The charge nurse in presence confirmed that both patients 13 and 14 were still inpatient at the hospital and had not been discharged.

On 7/31/2018 at 3 PM the charge nurse indicated once discharge planning started, the patient's physician would order discharge medications to the retail pharmacy. The retail pharmacy would dispense and deliver to the nursing unit. The charge nurse also indicated if there was a change to the discharge plan, or if the patient declined those medications upon discharge, their discharged medications would be returned to the retail pharmacy.

On 7/31/2018 at 4 PM the chief executive officer (CEO) of the hospital stated the outpatient (or retail) pharmacy was not part of the hospital. The hospital had an agreement with the retail pharmacy to dispense discharge medications for their patients upon discharge if their patients desired.

Review of the hospital policy and procedure, Discharge Drugs, last reviewed on 4/2018, indicated "The pharmacy shall NOT furnish drugs to patients upon release from the facility. The physician responsible for the patient shall provide the patient with a prescription that may be filled at [the hospital] out-patient pharmacy."

Review of the agreement between the hospital and the retail pharmacy, not dated, indicated if the hospital patient did not receive the discharge dispensed by the retail pharmacy after being discharged, the hospital staff would return the medications to the pharmacy within 7 days.

4. On 8/1/2018 at around 4 p.m. during an inspection of the hospital's night locker (a medication storage area designated for after-hour access, after the pharmacy is closed) in the presence of the director of pharmacy (DOP), there were two drawers with signage indicating the drawers may contained patients' own medications or medication brought from home upon admission. Inside one of those drawers, there was a sealed paper bag marked with Patient 15's name.

On 8/1/2018 at 4:10 PM at the Children Inpatient nursing unit, the charge nurse confirmed that Patient 15 had been discharged on 7/17/2018.

Review of the hospital policy and procedure, Patients Own Medication, last reviewed in 4/2018, indicated the nursing supervisor would give the medications to the patient or their family upon discharge.

ORGANIZATION

Tag No.: A0619

Based on observation, review of hospital documents, manufacturers' recommendation and staff interviews, the hospital failed to ensure the food and nutrition services was organized in a manner to meet the needs of the patients.

Findings:

During the survey from July 31 - August 3, 2018, several deficient practices were identified that could be directly related to the function of the organization of the department. These include:
1. The person in the position of the director of food and nutrition services department who did not meet the educational requirements and training that met state law. (cross refer A 620)
2. Inadequate provision of dietitian hours and consultation services that meets the needs of the patients. (cross refer A 621)
3. Lack of a system to incorporate the services and expertise of a registered dietitian in the nutrition care of patients.
4. Lack of menu that meets the nutritional needs of the patients. (Cross refer A 629)
5. Lack of an effective system to evaluate the nutritional needs of patients that includes follow-up assessment of patients, current professional standards.
6. Lack of implementation of a system that ensures the proper food safety practices. (cross refer A 749)
7. Lack of maintenance of food service equipment.
8. Lack of a data driven quality assurance, performance improvement program.

According to the review of personnel record, the hospital's director of food services (DFS) was hired seven months earlier. In an interview on August 1, 2018 starting at 4:00 PM, the DFS explained that he had been hired based on his experience and not on the education experience required by state law. He further explained that he did not manage the day- to- day operation of the kitchen but was responsible for the administrative functions of the department including food ordering, attending meetings and doing payroll. The DFS had not completed the food safety course for managers. He did not ensure that all food service workers completed food safety course (food handlers) required by state law.

The Policies and procedure manual did not reflect current food safety practices. The policy titled, "Receiving Food and Supplies" dated 4/26/17 under the subheading "Handling over-produced food, leftover food and extra food" states "over produced food which has not been on the steam table, may be stored for later use. The food services department saved food and failed to monitor the cooling.

The hospital had hired two part-time registered dietitians (RD) to provide nutrition care to the patients and limited food service responsibilities. The RDs were not always available to provide patient care services. The hours the one of the RDs were scheduled were not customary. RD 1's hours was from 4:15 AM to 10 AM. At this time, most of the patients are asleep and most other healthcare providers, the interdisciplinary team are not available. There is no RD scheduled on Thursday, Saturday and Sunday. There was a "stat" order for a nutrition consult for Patient 40 on one of the days, the RDs were not present (not scheduled) in the hospital. The nutrition consult was not completed until the next day. Stat orders are orders that are carried out with urgency. The RD 2 in an interview on August 3, 2018 starting 9:12 AM stated she completed the assessment the next day, this happened after Patient 40 who lost 11 pounds in 2 weeks and was transferred out to the acute care hospital as a result of the weight loss and refusal to eat.

The department did not have policy that addressed when follow up assessments were conducted on patients. Patient 39 who was admitted for over seven months was never reassessed. RD 1 and 2 in an interview on August 3, 2018 acknowledged there was no policy and procedure that addressed reassessment of patients. Patient 39 demonstrated problems with chewing during meal observation on August 1, 2018. The RD had assessed Patient 39 in December 2017 as not having any problems with chewing and swallowing.

One of the responsibilities of the RDs is the approval of the menus under federal and State laws. The menus were not analyzed to ensure that it was adequate to meet the recommended daily values for the population served.

The kitchen and cook were not provided with recipes to prepare dishes to ensure consistency in flavor, nutrients. The food service workers were also not provided with aprons to help protect the staff and patients from cross contamination.

The food and nutrition services did not evaluate its services to improve services provided.

DIRECTOR OF DIETARY SERVICES

Tag No.: A0620

Based on observation, review of hospital documents, manufacturers' recommendation and staff interviews, the hospital failed to ensure the director of food and dietetic services had the necessary training, experience and qualifications to manage the service appropriate to the scope and complexity of the service operations. This deficient practice resulted in poor food safety and sanitation practices that resulted in immediate jeopardy situation being declared on August 2, 2018. The director of food service did not:

1. Ensure safety practices for food handling including proper cool down, proper storage and food labeling.
2. Ensure that food service equipment was in good working order.
3. Ensure that staff had adequate resources to perform food service duties including recipes, food thermometers, aprons, garbage cans.
4. Ensure that the water temperature of faucet on the hand washing sink was appropriate for hand washing.
5. Ensure the hand washing sink and janitorial sink was installed in a manner to prevent cross-contamination of food and water sources.

Findings:

A review of personnel record indicated that the DFS did not have any of the educational training required by state law. California Health and Safety Code 1265.4 requires that a licensed health facility (hospital) who does not hire a full time registered dietitian shall employ a full -time dietary services supervisor who meets some educational requirements. The requirements outlined include: (b)(1) a baccalaureate degree with major studies in food and nutrition, dietetics or food management and one year of experience in a licensed health facility (2) a graduate of a dietetic technician training program approved by the ..... (3) a graduate of a dietetic assistant training program approved.. (4) a graduate of a dietetic services training program approved by the Dietary managers Association and is a certified dietary manager credentialed by the Certifying Board of the Dietary Managers Association, maintains Certification ..... (5) a graduate of a college degree with major studies in food and nutrition, dietetics, food management, culinary arts, or hotel management and is a certified dietary manager (6) a graduate of a state approved program that provides 90 or more hours of classroom instruction in dietetic service supervision .... (7) Received training experience in food service supervision in the military ...."

The Director of Food Service (DFS) stated that he did not have any of the outlined educational training and or experience. He stated in an interview on August 1, 2018 starting at 4:00 PM, he was hired based on his decades of experience in the food service industry not on educational achievements.

Inside the walk in refrigerator on July 31 at 11:45 AM, there were several containers of food that were leftover food from previous meals stored on the second shelf. There was a container of cooked rice dated 7/30, a container of ham also labeled 7/30. There was gravy in a container dated 7/29, a container labeled meatballs dated 7/26. There was also a large 6- quart container labeled Spanish rice filled almost to the brim.

There was a 20 lb. box of peas stored on the lower shelf in the refrigerator with manufacturer's instructions to "Keep frozen until ready to Cook".

The observation was shared with DFS at 11:48 AM. A request for cooling logs was made to evaluate whether the items were cooled appropriately. DFS stated in the interview on July 31, 2018 at 11:48 AM, there were no cooling logs because the hospital not save leftover items.

On August 1, 2018 at 10: 25 AM, there were leftover items observed stored on the top shelf in the refrigerator. There was sally mashed potato dated 7/26/18, diced potato dated 7/12/18, beans dated 7/23/18, red potatoes dated 7/12/18, rice dated 7/29/18 another container of rice dated 7/30, garlic potatoes 7/26. Cook 1 stated he believed there was a 3- day grace period to use leftover items and they do not monitor or use any logs. Cook 1 stated he had not considered the lack of monitoring of cooling logs.

The observation was shared with the DFS. The DFS stated on August 1, 2018 at 10:28 AM, the kitchen's priority was "to get breakfast and lunch out".

The failure of the hospital to monitor proper cooling of food, lack of staff knowledge and system to implement the process and the lack of corrective action on the part of the DFS after it had been identified the day before created an immediate jeopardy (IJ) situation that had the potential to result in food borne illness. The IJ was removed (abated) on August 3, 2018 at 3:05 PM.

During the tour of the kitchen on July 31, 2018 starting at 11:10 AM, during hand washing, the surveyor found the water temperature to be uncomfortably warm. There was no signage warning of the high water temperature. On August 1, 2018 at 10:20 AM during hand washing, the water temperature once again felt uncomfortably warm. In an interview with the DFS on August 1, 2018 at 11:00 AM about the high water temperature, DFS stated he was not aware that the water temperature was high and acknowledged the water temperature would not allow food service staff to wash their hands long enough (20 seconds) as recommended. The DFS stated one of the registered dietitians (RD 1) had requested that water temperature be increased and so it was turned up by the facilities department.

A temperature check of the water showed it as 126.1 degrees Fahrenheit (F). Warm water is more effective than cold water in removing the fatty soils encountered in kitchens. An adequate flow of warm water will cause soap to lather and aid in flushing soil quickly from the hands. High water temperature that makes hand washing uncomfortable may lead to poor handwashing practices by food employees.

According to the 2017 Food Code Section 5-202.12 (A) "A handwashing sink shall be equipped to provide water at a temperature of least 100 degrees F through a mixing valve or combination faucet". ASTM Standards for testing the efficacy of handwashing formulations specify a water temperature of 100 to 108°F. American Society for Testing and Materials (ASTM) , is an international standards organization that develops and publishes voluntary consensus technical standards for a wide range of materials, products, systems, and services.
Also attached to the faucet was an eye wash station. Higher water temperatures are harmful to the eyes and can enhance chemical interaction with the skin and eyes. In addition, the hand washing sink was located less than six inches from the drain board of the food preparation sink. There was no splash- guard preventing cross contamination of dirty soapy water from splashing on to food that may be prepared on the preparation sink.

In the spice cabinet in the kitchen, there was an opened one-gallon container of BBQ sauce dated "6/8/18". Manufacturer's recommendation stated "Refrigerate after opening". The food service manager present during the observation, stated on July 31, 2018 at 11:19 am, she was not aware that the sauce required refrigeration. FSM indicated that the date on the containers is the date received. FSW stated that they do not put date items were opened because they had been instructed by RD 1 to only put date the item was received. There were items such as spices, not labeled or dated.

There was no consistent labeling system. There were other items in the kitchen that had expiration dates and not dated when they were received. FSM who was present during the observation stated the errors may be due to new and agency employees that were recently hired who may have learned dating and labeling differently.

Inside the walk in freezer, there were item stored all the way to the roof of the freezer with very little clearance. The food items were stored very close to the fan on the condenser. The items were very tightly packed that poor air circulation was reduced. In an concurrent interview observation with the DFS at 2:03 PM, DFS indicated that the freezer space was limited.

At 1:52 PM on July 31, 2018, a large plastic measuring cup was observed stored in a storage container of flour. The FSM who was present during the observation removed the cup.

Equipment Maintenance
1. At 2:15 PM on July 31, 2018, the faucet in the 2-compartment sink was leaking hot water in the sanitizing compartment water. The constant dripping of the hot water into the solution had the potential to dilute the concentration, thereby making it ineffective.

2. At 2:47 PM, the temperature gauge for the dish machine was broken and temperature was stuck at 140 degrees F for both the wash and rinse cycles. Food service worker (FSW 3) who operated the machine stated the water temperature of machine is checked using a hand-held food thermometer. The temperatures are recorded while watching and listening to the different cycles. The FSM stated in a concurrent observation that she could not remember how long the thermometer had broken and when the food service staff started inserting a food thermometer in the water well to check water temperatures. The FSM flicked the temperature gauge with her finger, which moved the thermometer from 140 to 130 degrees F. The temperature gauge did not move after several wash cycles were observed. The process was unsafe due an increased the risk of burn as the water splashed as it was flowing and circulating the well.

Review of the hospital document titled "(name of facility) Dishwasher Temperature Log" for the month July 2018 had a recording of 130 degrees F for the wash cycle (28 out of 31 days) for breakfast, 25 of 31 days for lunch and 27 of 31 days for dinner. For the final rinse cycle temperature of 140 degrees (F) was recorded 29 out of 31 days for breakfast, 29 out of 31 days for lunch 28 out of 31 days for dinner.

According to the 2017 Food Code Section 4-602.11 (C) "Ambient air temperature, water pressure and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use."

3. There was water spewing out leaking from the faucet in the chemical storage/janitorial area outside the kitchen. Attached to the faucet was a two paired hose bib connection, the hoses were red and black in color. A hose bib(b) is a "threaded faucet also known as a wall hydrant". The end of the red hose was inside a blue bucket on the floor with a dark brown solution, with bubbles resembling soap or detergent. The connection did not have an anti-siphon or back-flow prevention device. There was a significant build- up of a brown colored substance on the rack adjacent to the faucet, resembling rust. There was a similar colored substance on the horizontal bracket that held the water pipe to keep the faucet in place. The presence of rust could be an indication of the presence continued moisture in the area.

According to the 2017 Food Code Section 5-203.14. "a plumbing system shall be installed to preclude backflow of a solid, liquid, or gas contaminant into the water supply system at each point of use at the food establishment, including on a hose bibb if a hose is attached .... and backflow prevention is required by law, by: (a) providing an air gap as specified under § 5-202.13 or (b) installing an approved backflow prevention device ..."

The facilities director in an interview on August 1, 2018 at 3:30 PM indicated he was not aware of the leaking of the faucet. In an interview with the FSD on August 1, 2018 starting at 4: 00 PM, the FSD indicated he made reports to the facilities department about the various equipment that needed repairs. The FSD stated the reports were in form of email but was unable to provide evidence of the reports because he "does not keep email".

Recipes
There were observations with Cook 2 and Food service worker (FSW) 1 preparing food without recipes. Cook 2 prepared Cheese Enchilada Casserole without a recipe. FSW 1 was observed on July 31 and August 1, 2018 preparing fruit salad without a recipe. The lack of recipes was discussed with the FSW on July 31, 2018 at 1:40 PM. The FSM in the interview stated that there were some recipes from the new menu cycle but the hospital did not have a complete set of recipes for all items prepared. The DFS stated in the interview on August 1, 2018 starting at 4:00 PM that the FSM was responsible for the kitchen and he was responsible for administration.

Aprons
During observations in the kitchen from July 31 through August 3, 2018, only three employees were observed wearing aprons as they performed food service duties. Other food service workers including those preparing food and helping with the assembly of meals did not wear aprons.

In an interview with the group of food service workers on August 3, 2018 at 2:55 PM, a random FSW explained that the hospital does not provide them with uniforms and the expectation is that if they need aprons they will have to purchase the aprons themselves. FSW 3 who had an apron stated in an interview on August 1, 2018 at 2:15 PM, that he purchased the apron he had and takes it home to launder. Cook 2 who was also wearing an apron stated in an interview on August 1, 2018 at 10:47 AM, that the hospital did not provide him with the apron. Cook 2 stated that the plastic apron melt when he gets close to the stove and heating equipment. The FSM who was present during the interview stated the hospital was "between vendors" and are currently not being provided with aprons.

A review of the contracts between the previous and current laundry services provider, indicated that Contractor 1, (previous provider) provided kitchen towels, aprons, chef's coat, cook shirts and pants as part of the service (Exhibit B). A review of the contract for Contractor 2, ( current provider) did not indicate if similar items were provided. There was a list of items as part of the contract but no aprons or kitchen towels were on the list. In an interview with the Laundry Supervisor (LS) on August 3, 2018 at 3:00 PM, LS acknowledged that the laundry services did not provide aprons.

The lack of aprons for food service staff exposed the patients to possible cross contamination of food from clothing. Dirty clothing may harbor diseases that are transmissible through food. Food employees who inadvertently touch their dirty clothing may contaminate their hands. This could result in contamination of the food being prepared. Food may also be contaminated through direct contact with dirty clothing. (Food Code Annex)

According to the 2017 Food Code Annex "All of the following control measures should be implemented regardless of the food preparation process used: ... ... Prevention of cross-contamination of ready-to-eat food or clean and sanitized food-contact surfaces with soiled cutting boards, utensils, aprons, etc., or raw animal foods.

QUALIFIED DIETITIAN

Tag No.: A0621

Based on observations, review of hospital documents, clinical record review and staff interviews, the hospital failed to ensure that the contracted registered dietitians adequately supervised the nutritional aspects of patient care. The frequency of consultations did not meet the nutritional needs of the patients when registered dietitians failed to:
1. Approve and analyze patient menus.
2. Perform and document nutrition assessments according to current standards of practice.
3. Collaborate with nursing services and other services to plan and implement patient care as necessary to meet the nutritional needs of the patients.
4. Provide oversight of the food service operation and its director of food services who did not meet state educational requirements for the position.
5. Identify deficient food safety practices that resulted in an immediate jeopardy situation.
6. Provide adequate coverage to meet the needs of the patients.
7. Develop a quality assurance performance improvement program.

Findings:

A review of contracts showed that the hospital had entered into contracts with two dietitians (RD 1 and RD 2) to provide services "in the field of dietary and nutritional services". According to stipulations on the contracts, both RD 1 and RD 2 services' could each not exceed 20 hours per week.

In an interview with RD 1 on August 1, 2018 starting at 9:00 am, RD 1 indicated her work hours are from 4:15 am to 10:30 am, three days a week. RD 1 explained that RD 2 also works three days a week. Both RDs work the same two days (Mondays and Fridays) but their hours do not overlap. RD 1 also works on Wednesdays, while RD 2 works on Tuesdays. There is no RD coverage on Thursdays and weekends.

In the interview with RD 1 on August 1, 2018, RD 1 indicated that in addition to clinical nutrition responsibilities, she does a monthly inspection and audit of the kitchen. RD 1 indicated that she does in service education of the kitchen staff related to the menu. RD 1 further stated in the same interview that the hospital hired the RDs mainly for "patient care" and have no oversight of the kitchen and food service responsibilities.

An interview with RD 2 on August 3, 2018 starting at 9:12 am, RD 2 stated the hospital had limited the hours of services to no more than 80 hours a month and they could not exceed the hours.

Menu
There are no regulatory requirements for who can write or prepare a menu. However, there are regulatory requirements for menu approval of both regular and therapeutic diets by the registered dietitian. There was no notation that either RD 1 or RD 2 approved the menu. A review of the five-week hospital menu showed the names of the two different RDs who prepared different weeks of the menu. RD 2's name was printed on two of the weeks as preparing the menu. The name of another RD (RD 3) was printed on some of the menus. The approval of the menu signifies that it has been reviewed and deemed appropriate in terms of the nutrient content, texture, population, cultural appropriateness, disease and specialized needs of the patients among other criteria, by the hospital dietitian who is knowledgeable about the patients in that hospital.

RD 2 stated in the interview on August 3, 2018 starting at 9: 30 am that she updated two of the weeks of the menus. She stated she had believed that her name printed on the menu implied that she had approved the menu. RD 1 who was present during the interview and RD 2 were unable to explain and demonstrate how they approved menus if the name on the menu was that of another RD (RD 3) who according to RD 2 no longer worked for the hospital.

During kitchen observations on July 31 and August 1, 2018, food service workers were observed preparing different entrée items without recipes. RD 2 in the same interview stated that she had provided recipes for menu for the weeks she had written. She acknowledged neither she nor RD 1 ensured that the food service staff had recipes to prepare all items on the five week cycle menu. RD 2 stated the menu had not been analyzed to evaluate the adequacy of nutrients and validate that it would meet the nutritional needs of the patient population because the hospital did not have the computer program that analyzes nutrients. (Cross refer A628)

Diets
Clinical review of Patient 39 showed Patient 39 was admitted to the hospital with medical diagnoses of diabetes in addition to psychiatric diagnoses. Diabetes a medical condition in which the body does not produce enough insulin resulting in high blood sugar. The physician ordered diet was 2000 Cal (calorie) ADA diet- diabetic diet. The ADA (American Diabetic Association) diet is an outdated diet. In a position statement in 2002, the ADA "recommended that the term "ADA diet" no longer be used, since the ADA no longer endorses any single meal plan or specified percentages of macronutrients as it has done in the past".

A review of the 2018 menu showed that there was 1800 Cal ADA and 2000 Cal ADA diets on the menu. RD 2 in the same interview of August 3, 2018 starting at 9:12 AM stated that the diets were served because that was what "was ordered by the physician". RD 1 and RD 2 acknowledged neither provided training to the medical staff. RD 2 stated that the physicians were not educated on the fact that the ADA diet was outdated. A review of the facility diet manual showed that the diet listed for the treatment of diabetes was the consistent carbohydrate diet. In an interview with the Medical Director (MD) on August 3, 2018 at 11:35 AM, the MD indicated that he had not been aware that the ADA diet was outdated and that he would not have continued to order such diets had he been educated about it.

Nutrition Assessments
The quality of the information nutrition gathered and used to develop nutrition assessments and medical nutrition therapy was not adequate to the scope and complexity of the population served. Assessments by the RDs included type of diet, height, weight, estimated caloric needs per day and a plan which was mostly checked off as "provided basic nutritional services".

In an interview with RD 1 on August 1, 2018 starting at 9:10 am, RD 1 stated that all patients are assessed within 72 hours of admission. RD 1 provided a document titled "MyPyramid Food Intake Pattern Calorie Levels" which RD 1 indicated was used in estimating nutrition needs of patients. The chart which assigns calorie level based on sex, age and activity level does not take into consideration height, weight, overweight or underweight determination, protein and fluid needs.

According to the 2006 ADA (American Dietetic Association) Core Registered Dietitian Standards of Practice Indicators, the RD in Behavioral health "completes a more detailed analysis of the indicators to evaluate the complexity of problems and correlate one problem to another (i.e. using advanced clinical judgement skills reflecting the holistic focus of behavior health care as a complex disorder). According to Academy of Nutrition and Dietetics (formerly American Dietetic Association) RDs in behavioral Health are urged to be familiar with the Standard of Practice and Standard of Professional Performance in Behavioral Health Care.

A review of five clinical records showed that this chart was used to determine the caloric needs of all the patients. The current standard of practice is to evaluate caloric, protein and fluid needs. The Academy of Nutrition and Dietetics (2017) states "the Mifflin-St Jeor equation is the most accurate (equation to use for estimating nutrient needs) for normal and obese individuals". 0.8 gm per kilogram body weight is the calculation for protein needs and 30 milliliters (a measure of volume) x kilogram body weight is the calculation for fluid needs.

In the interview with RD 2 and RD 1 on August 3, 2018 starting at 9:12 AM, RD 2 stated that she was aware of nutrition assessments done with calculations of calories, protein and fluid and does so in her consultant practice in another level of care but that they have never done so at this hospital. Neither RD 1 who was present during the interview and RD 2 provided any rationale as to why they never implemented the current practice for nutrition assessment calculations and formula at the hospital.

A review of the nursing initial assessment form had an incomplete information on screening patients for nutritional risk. There were a set of questions with assigned points. The form is titled "RNs Mental Health Nursing History and Assessment -AIP" dated 11/2015. However, there was no instruction on what those points indicated or what the nurses needed to do if any of the boxes was checked. In an interview with the two licensed nurses (LN N1 and CN N1) on the adult inpatient unit on August 2, 2018 at 11:30 AM, both indicated they did not understand the section on the form and did not routinely complete the section. The Chief Nursing Officer (CNO) in an interview on August 2, 2018 at 1:37 PM stated there were no policies that explained the Nutritional Screening scoring process.

RD 1 stated in the August 3, 2018 interview that the form was revised about a year or so ago but the instructions were omitted in the latest revision. A review of the hospital document titled "RNs Mental Health Nursing History and Assessment -AIP" dated "7/2004" under the subheading "Nutritional Assessment" listed eleven different criteria with points associated with nine of them. There was an area for total points and instructions that if a score of three is identified, dietary consult is needed within 24 hours.

A review of the assessment questions indicated the screening was not tailored to the mental health population served. A 2006 document titled "Assessment of Eating Behaviors for patients with Acute Mental Illness" by The Dietetics in Developmental and Psychiatric Disorders Practice Group of the American Dietetic Association, lists screening and assessment questions appropriate for this group. The lists included assessment of cognitive behaviors such as decreased awareness of need to eat, paranoid about food, Eating Behaviors such as bites too large for safe swallow, social behavior such as demanding behavior in the dining room as part of the assessment for the population served. These are some of the same behaviors documented in the patients in the hospital.

Collaboration with other services
1. Patient 40 was admitted with diagnoses including schizophrenia. Patient 40 believed his food was being poisoned and so he refused to eat. The physician's order for Patient 40 was a regular diet and nutritional supplements three times a day. Nursing staff did not observe Patient 40 consuming meals from 7/12/18, date of admission through 7/26/18 when he was transferred to the acute care hospital. Patient 40 refused all nutritional supplements from 7/12/18 through 8/2/18. Patient 40 weighed 138 lbs. on admission, lost 11 pounds in 14 days before he was transferred to an acute care hospital for rehydration.

Clinical record review of Patient 40 indicated the RD completed a nutrition assessment on the day of admission. The RD did not complete any other assessments or documentation when Patient 40 continued to refuse meals and lost 11 pounds. Nursing notes indicated that nurses attempted to provide meals in sealed containers to reassure Patient 40 that meals were not tampered with. In an interview with LN N1 on August 2, 2018 at 12:30 PM, LN N1 indicated Patient 40 was offered "cup of noodle". The noodle dish is prepared by adding water to dehydrated noodle. The container had to be opened to prepare the item and may have contributed to why Patient 40 did not consume it. Other prepackaged products such as packaged frozen dinners, could have been offered to Patient 40 that would have not been opened to prepare and serve. The Foodservice manager (FSM) on August 2, 208 at 4: 25 PM stated that they have prepackaged products that they occasionally obtain for patients such as those on Kosher diets that would have been appropriate for Patient 40 had the RD requested it.

LN N1 acknowledged in the interview on August 2, 2018 at 12:40 PM the nursing staff did not refer Patient 40 to the RDs. LN N1 stated in the same interview that it was not part of the hospital protocol to call the RD if a patient does not eat, they (nursing staff) call the physician. RD 2 in the interview on August 3, 2018 starting at 9:12 am stated that she was not aware of Patient 40's weight loss and his meal refusals. RD 2 indicated she attempted to reassess Patient 40 when she received a "stat" order from the physician for a nutrition consult on 7/26/18 but on 7/27/18 when she visited Patient 40, he was eating.

2. During meal observation on July 31, 2018 at 12:15 PM, four of the eight patients present in the children's unit did not consume all their meals. CNA N1 who was present stated some of the patients may not have been hungry because they may have just had snacks. CNA N1 indicated one the patients just had BBQ chips less than one hour before lunch and another was just given two cupcakes, of which he had consumed one, for cleaning his room. CNA N1 stated on July 31, 2018 at 12:30 PM, the patients are given snacks and also receive food as incentives and rewards.

According to the University of Rochester Medical Center "using food as a reward or as a punishment, however, can undermine the healthy eating habits that you are trying to teach your children. Giving sweets, chips, or soda as a reward often leads to children overeating foods that are high in sugar, fat, and empty calories. Worse, it interferes with kids' natural ability to regulate their eating. It also encourages them to eat when they are not hungry to reward themselves". ActionforHealthyKids.org states that the goal of rewarding ...is to help internalize desirable behaviors and create motivation ... that comes from inside and that effective rewards should promote healthy living ..." Both RDs indicated on August 1 and 3, 2018 at 9:15 am they were not aware that food was being used as an incentive in the children's unit.

3. During the discussion about participation in the Pharmacy and Therapeutic (P&T) Committee, RD 1 and RD 2 indicated on August 3, 2018 at 9:48 AM, that they do not participate in the meetings because they are held on days or times they are not scheduled to be in the hospital. RD 1 stated on August 3, 2018 at 9:50 AM, the RDs also do not attend "due to other obligations". Physician education, nutrition therapy including use of food as an incentive and updating of diet manuals would be appropriate topics that the RDs could have been brought forward to the P&T committee.

4. On August 2, 2018 at 4:30 PM, Food Service Manager (FSM) made changes to the pediatric menu because it was "not enough food for the children". FSM in a concurrent interview and observation stated in response to getting RD approval for diet/menu changes, she does not know how to reach the RD and would have to get the hospital operator to reach them. The hospital did not have a system in place to ensure communication existed between the RDs and food service staff.

Oversight
During the tour of the kitchen, there were many deficient practices identified resulting in immediate jeopardy. In the interviews with RD1 on August 1, 2018 and RD 1 and 2 on August 3, 2018, RD 1 and RD2 stated they had limited oversight of the kitchen and do in services and monthly kitchen sanitation checks. RD 1 stated in the August 3, 2018 interview that the RDs do not have any authority to speak with the food and nutrition staff.

Diet Manual
A review of the diet manual indicated that the last it was approved was in 2014. The community standards for approval of menu is yearly.

QAPI
In the interview on August 3, 2018 starting at 9:12 AM, both RD 1 and RD2 indicated they currently do not have any performance improvement projects going on and did not develop any in the past. RD 1 stated her monthly audits are presented to the administrator and director of food services. A review of the facility document titled "Sanitation Report" completed monthly by RD 1 from November 2017 through April 2018 showed poor labeling as one of the identified concerns. Most of the other deficient practices identified during the survey were however, not identified by RD 1.

THERAPEUTIC DIETS

Tag No.: A0629

Based on review of menu, review of clinical records and staff interviews, the hospital failed to ensure that the menu was analyzed to determine that it met the needs of all of its patients. The five-week menu currently used by the hospital was developed by different dietitians and some of which do not have recipes to determine its ingredients, preparation methods and therefore its nutrient content. This had the potential to affect the nutrition status of all 50 patients admitted during the survey. In addition, the hospital failed to ensure the nutritional needs of two sampled patients (Patients 39 and Patient 40) were met in accordance with recognized dietary practices. These failures resulted in weight loss of 11 pounds in 14 days for Patient 40 and potential to choke in Patient 39. (Cross refer A 621)

Findings:

A review of week 4 of the five-week hospital menu did not indicate the registered dietitian (RD) approved the menu. The approval of the menu signifies that it has been reviewed and deemed appropriate in terms of the nutrient content, texture, population, cultural appropriateness, disease and specialized needs of the patients among other criteria, by the hospital dietitian who is knowledgeable about the patients in that hospital.

During kitchen observations on July 31 and August 1, 2018, food service workers were observed preparing different entrée items without recipes. On July 31, 2018 at 1:45 PM, Food service worker (FSW 1) prepared a fruit salad with cantaloupe, honeydew melon, pineapple and grapes and poured over the fruit unmeasured quantity of drinkable yogurt. In a concurrent interview and observation, FSW 1 stated there was no recipe for the fruit salad.

On August 1, 2018 at 3:00 PM, Cook 1 was interviewed on the preparation methods used to prepare the Cheese enchilada that had been prepared for dinner. Cook 1 said he did not have a recipe but followed the directions on the box of the Enchiladas. According to the menu, patients on regular diet were to be served 3 ounces of Cheese enchilada bake casserole. It was not clear if the other ingredients were required to make the cheese enchilada bake. The serving size on the box of the Cheese enchilada was two. The two enchiladas will provide 17 grams of protein. If the 3 ounces written as portion implied the protein content of the enchilada was 3 ounces, the amount of the enchilada given was less than 3 ounces. Three ounces is 21 grams of protein, the two enchiladas were 17 grams (or 2 -1/2 ounces) protein, four grams less than was planned on the menu.

There were seven patients on a Double Portions (DP) diet. There were no written menu or instructions on how much food to serve patients on this diet. During meal service observation on August 1, 2018 at 10:47 AM, patients on double portions diet were served a chicken breast and one wing of BBQ chicken. Cook 2 in a concurrent observation and interview stated the patients on double portion diets were to receive double the protein on all meals but was unclear whether there were increases for other items on the meal such as bread, vegetables. Cook 2 dished out double the vegetable (broccoli) after the surveyor asked questions. The breast and wing served was not twice the protein.

In an interview with RD 1 on August 1, 2018 starting at 9:12 am, RD 1 stated she was unsure of the serving of double portion, believes it was double meat but unsure of the exact amount. RD 2 provided a document titled "Menu pattern Regular diet and Double Portions Diet" dated 3/1/12. According to the document, patients on double portions diet receive double the serving of bread at breakfast: two boxes of cold cereal versus one for patients on regular diet, four slices of bread vs two slices during breakfast. For lunch, patients on double portions receive 5 ounces of protein versus 3 ounces for patients on regular diets. The DP diet receive double starch, vegetables and whole wheat bread. For dinner, the pattern is the same as lunch.

A review of week 4 of the five- week menu showed limited variety in the starches and vegetables offered. There were repetition of food items from one meal to another or day- to-day. For example on 7/31/18, Tuesday, broccoli with cheese sauce was served for lunch. For dinner, patients were served bean broccoli salad. On Wednesday 8/1/18, peas/glazed carrots was the vegetable for lunch and glazed carrots was the vegetable for dinner. Patients received garlic mashed potato on Monday for dinner, Wednesday for lunch, oven browned potatoes for lunch on Thursday and mashed potatoes for dinner also on Thursday. For Thursday lunch, roasted red potatoes. Meal repetition limits the kind of nutrients a patient will receive and may affect intake due to reduced satisfaction.

RD 2 stated the menu had not been analyzed to evaluate the adequacy of nutrients and validate that it would meet the nutritional needs of the patient population because the hospital did not have the computer program that analyzes menus for their nutrients. (Cross refer A629)

Diets
Clinical review of Patient 39 showed Patient 39 was admitted to the hospital with medical diagnoses of diabetes in addition to psychiatric diagnoses. Diabetes a medical condition in which the body does not produce enough insulin resulting in high blood sugar. The physician ordered diet was 2000 Cal (calorie) ADA diet- diabetic diet. The ADA (American Diabetic Association) diet is an outdated diet. In a position statement in 2002, the ADA "recommended that the term "ADA diet" no longer be used, since the ADA no longer endorses any single meal plan or specified percentages of macronutrients as it has done in the past". A review of the 2018 menu showed that the RDs had an 1800 Cal ADA and 2000 Cal ADA diets as part of the diets offered. RD 2 in the same interview of August 3, 2018 starting at 9:12 AM stated that the diets were served because that was what was ordered by the physician.

RD 2 stated that the physicians were not educated on the fact that the ADA diet was outdated. A review of the facility diet manual showed that the diet listed was the consistent carbohydrate diet. In an interview with the medical director (MD) on August 3, 2018 at 11:35 AM, MD stated that the RDs did not inform him about the needs of the department. MD stated was not aware the ADA diet was outdated.

Nutrition Assessments
In an interview with RD 1 on August 1, 2018 starting at 9:10 AM, RD 1 stated that all patients are assessed within 72 hours of admission. RD 1 provided a document titled "MyPyramid Food Intake Pattern Calorie Levels" which RD 1 indicated used in estimating nutrition needs of patients. The chart which assigns calorie level based on sex, age and activity level does not take into consideration height, weight, overweight or underweight determination, protein and fluid needs.

According to the 2006 ADA (American Dietetic Association) Core Registered Dietitian Standards of Practice Indicators, stated the RD in Behavioral health "completes a more detailed analysis of the indicators to evaluate the complexity of problems and correlate one problem to another (i.e. using advanced clinical judgement skills reflecting the holistic focus of behavior health care as a complex disorder)

A review of five clinical records showed that this chart was used to determine the caloric needs of all the patients. There were no complex analysis of the nutritional needs of each of the patients reviewed. The current standard of practice is to evaluate caloric, protein and fluid needs. The Academy of Nutrition and Dietetics (2017) states "the Mifflin-St Jeor equation is the most accurate (equation to use for estimating nutrient needs) for normal and obese individuals". 0.8 gm per kilogram body weight is the calculation for protein needs and 30 milliliters (a measure of volume) x kilogram body weight is the calculation for fluid needs. In the interview with RD 2 and RD 1 on August 3, 2018 starting at 9:12 AM, RD 2 stated that she was aware of nutrition assessments done with calculations of calories, protein and fluid and does so in her consultant practice in another level of care but that they have never done so at this hospital. Neither RD 1 who was present during the interview and RD 2 provided any rationale as to why they never implemented the current practice for nutrition assessment calculations and formula at the hospital.

Menu
There was no difference in the amount served to children and adults. Tuesday and Wed, same for all three meals. The amounts for other days were identical with the exception of few entrees. The age group of the children during the survey was 6 - 12 years old. According to the hospital document provided by the RDs titled MyPyramid Food Intake Pattern Calorie Levels" by the USDA the caloric need for the children in this age group is between 1200 to 1800 calories for sedentary activity. Serving the same food to children and adults whose caloric need is 2000 to 2600 calories is not appropriate. Excessive amounts of food could result in overeating resulting in inappropriate weight gain.

Nutritional Needs
1. Patient 40 was admitted with diagnoses including schizophrenia. Patient 40 believed his food was being poisoned and so he refused to eat. The physician's order for Patient 40 was a regular diet and nutritional supplements three times a day. Nursing staff did not observe Patient 40 consuming meals from 7/12/18, date of admission through 7/26/18 when he was transferred to the acute care hospital. Patient 40 refused all nutritional supplements from 7/12/18 through 8/2/18. Patient 40 weighed 138 lbs. on admission, lost 11 pounds in 14 days, before was transferred to an acute care hospital for rehydration. A 7.9 % weight loss in two weeks, is a severe weight loss. According to current standard of practice weight loss of greater than 5% in one month is severe.

Clinical record review of Patient 40 indicated the RD completed a nutrition assessment on the day of admission. The RD did not complete any other assessments or documentation when Patient 40 continued to refuse meals and lost 11 pounds. Nursing notes indicated that nurses attempted to provide meals in sealed containers to reassure Patient 40 that meals were not tampered with. In an interview with LN N10 on August 2, 2018 at 12:30 PM, LN N10 indicated Patient 40 was offered "cup of noodle". Cup of noodle is prepared by adding water to dehydrated noodle. The container had to be opened to prepare the item and may have contributed to why Patient 40 did not consume it. Other prepackaged products such as some packaged dinners, could have been offered to Patient 40 that would have not been opened to prepare and serve. The Food service manager (FSM) on August 2, 208 at 4: 25 PM stated that they have prepackaged products that they occasionally obtain for patients such as those on Kosher diets that would have been appropriate for patient 40 had the RD requested it.

LN N10 acknowledged the nursing staff did not refer Patient 40 to the RDs. LN N10 stated in the same interview that it was not part of the hospital protocol to call the RD if a patient does not eat, they call the physician. RD 2 in the interview on August 3, 2018 starting at 9:12 AM stated that she was not aware of Patient 40's weight loss and his meal refusals. RD 2 indicated she attempted to reassess Patient 40 when she received a "stat" order from the physician for a nutrition consult on 7/26/18 but on 7/27/18 when she visited Patient 40, he was eating. There was no documentation of the consult.

2. During meal observation on August 1, 2018 at 12:10 PM, in the adult in-patient unit, Patient 39 was served the following: BBQ Chicken, broccoli, mashed potato in a container. She received an additional container with yogurt, jello which was described as soft diet. Patient 39 had difficulty biting into the BBQ chicken. Patient 39 moved the large chicken breast along every area of her mouth trying to cut into the chicken and could not bite into it. About a minute or so later she pulled it out of her mouth and tore off pieces of chicken with her hands and shoving large pieces of the meat in her mouth. It looked like she was going to choke. The nursing staff in the room did not redirect her to slow down or offer to cut the food.

Observation showed Patient 39 was edentulous (no teeth). Review of clinical record showed Patient 39 was admitted to the facility about seven and a half months before and had been placed on a 2000 calorie ADA diet. She had been assessed by the RD on 12/15/17. The RD marked that she did not have difficulty chewing or swallowing. There was no other documented evidence that the RD reassessed her.

A review of her master treatment Plan - Interdisciplinary Plan of care did not identify her lack of teeth as a problem. On 2/23/18, the care plan under the heading Dietitian, stated "No dietary issues at this time". There was no documentation in her clinical record that she had no teeth or use of dentures. In an interview with CNA N2 on August 2, 2018 at 11:30 AM, CNA N2 stated Patient 39 does not have teeth "but she eats". Patient 39 was not properly assessed to ensure that the diet and texture were appropriate to prevent choking.
RD 2 in an interview on August 3, 2018 at 9:48 AM, stated Patient 39 would not eat ground meat and would want regular meats from the menu. There was no documented evidence that the Patient 39 would not eat the food of the appropriate texture to prevent accidental choking.

Patient 39 was not reassessed after the initial assessment. Professional standards of practice require reassessment of patients in a hospital. There was no policy in place that guided the practice of when reassessment will be conducted.

3. During meal observation on July 31, 2018 at 12:15 PM, four of the eight patients present in the children's unit did not consume all their meals. CNA N1 who was present during the observation stated some of the patients may not have been hungry because they may have just had snacks. CNA N1 indicated one the patients just had BBQ chips less than one hour before lunch and another was just given two cupcakes, of which he had consumed one, for cleaning his room. CNA N1 stated on July 31, 2018 at 12:30 PM, the patients are given snacks and also receive food as incentives and rewards.

According to the University of Rochester Medical Center "using food as a reward or as a punishment, however, can undermine the healthy eating habits that you are trying to teach your children. Giving sweets, chips, or soda as a reward often leads to children overeating foods that are high in sugar, fat, and empty calories. Worse, it interferes with kids' natural ability to regulate their eating. It also encourages them to eat when they are not hungry to reward themselves". ActionforHealthyKids.org states that the goal of rewarding ...is to help internalize desirable behaviors and create motivation ... that comes from inside and that effective rewards should promote healthy living ..." Both RDs indicated on August 3, 2018 at 9:15 AM they were not aware that food was being used as an incentive or reward in the children's unit.

4. During the discussion about participation in the Pharmacy and Therapeutic (P&T) Committee, RD 1 and RD 2 indicated on August 3, 2018 at 9:48 AM, that they do not participate in the meetings because they are held on days or times they are not scheduled to be in the hospital. RD 1 stated on August 3, 2018 at 9:50 AM, the RDs also do not attend "due to other obligations". Physician education, nutrition therapy including use of food as an incentive and updating of diet manuals would be appropriate topics that the RDs could have been brought forward to the P&T committee.

5. On August 2, 2018 at 4:30 PM, Food Service Manager (FSM) made changes to the pediatric menu because it was "not enough food for the children". FSM in a concurrent interview and observation stated in response to getting RD approval for diet/menu changes, she does not know how to reach the RD and would have to get the hospital operator to reach them. The hospital did not have a system in place to ensure communication existed between the RDs and food service staff.

6. During meal observation in the Children's In Patient (CIP) unit on July 31, 2018 at 12: 20 PM, Patient 24 asked for water while eating. There were no water cups, pitchers or other visible source of water in the room where the meals was being consumed. The CNA N1 who was present during the meal told the patient there was juice on the table. The patient was not provided water during that meal.

During meal observation on August 1, 2018 at 12:10 PM the Adult in patient unit, Patient 38 had asked for ice. The Mental Health Technician (MHT) who supervised the patients stated there was no ice available. Patient 38 continued to ask for ice singing "ice, ice, baby" with the request for ice getting louder. MHT scooped ice from the container that held the frozen dessert and provided to Patient 38. This ice could have been a potential source of contamination.

In an interview with the MHT on August 1, 2018 at 12:30 PM, MHT stated the patients only have access to water. In an interview with the Food service Manager (FSM) on August 2, 2018 at 4:05 PM, FSM stated there is no water on the menu and so it is not provided. FSW also stated they do not serve ice.

In an interview with the RD 1 and RD 2 on August 3, 2018 starting at 9:12 AM, RD 1 stated the kitchen does not provide water to the patient units. She indicated there was a water foundation in the hallway where the children could access water. She did not respond when the surveyor asked if the expectation was that the children leave the table to drink water from the fountain. Regarding the adult unit, RD 2 stated she was unclear why water was not provided and that possibilities include water being thrown at other patients.

DIETS

Tag No.: A0630

Based on review of clinical record and staff interviews, the facility failed to ensure that diet orders were ordered by the practitioner responsible for the care of the patient. Two sampled patients (Patients 37 and 38 ) did not have diet orders prescribed by their physicians.

Findings:

Clinical record review for Patient 38 indicated the patient was admitted on 7/31/18 with diagnoses including bipolar disorder. The physician did not order a diet for the patient. The patient was served a Regular diet. According to the Diet requisition list for August 1, 2018. During meal observation, Patient 38 received a regular diet.

Patient 37 was admitted on 8/1/18. A review of the Physician Admission orders showed no diet was ordered for the patient. The lack of a diet order was not identified by the RD who had completed a Nutrition/Dietary assessment on 8/3/18. The Patient was served a regular diet.

In an interview with LN N9 on August 3, 2018 at 12:30 PM, LN N2 stated the RN who carried out the order was not available for interview but must have forgotten to verify the diet orders but that the physician wrote the order himself.

MAINTENANCE OF PHYSICAL PLANT

Tag No.: A0701

Based on observation and interview the facility failed to develop and maintain the physical plant in a manner that assured the safety and well-being of patients.

Failure to ensure maintenance of the physical environment may compromise the medical status of patients and the ability for staff to care for patients.

Findings:

Basement

1) On 7/31/18 at 10:46 a.m., the evaluator observed that in the dietary storage room there was an accumulation of dust at a ceiling air return register.

On 8/1/18 between 8:30 am and 2:30 pm the following conditions existed at the facility.


1st Floor Kitchen

2) The evaluator observed the temperature of the water at the hand wash sink was tested with a result of 120 oF (degrees Fahrenheit). Further observation revealed there was no posted sign warning about the 120 of water temperature.

During an interview at the same time as the observation, the Director of Facilities acknowledged the water temperature was 120 oF, that there was no posted signage that the water was 120 oF.

3) The evaluator observed there was a squeeze application bottle containing machine oil laying on an electrical conduit next to a reach in refrigerator use for spice storage at cooking area of the kitchen.

During an interview at the same time as the observation a kitchen staff stated that oil was used to loosen screw on the cooking equipment.

4) The evaluator observed there was a 2 vertical foot accumulation of black material at the corner of a tiled wall in the dishwashing area.

During an interview at the same time as the observation the Director of Facilities stated the kitchen is cleaned daily, but that spot must have been missed.


2nd Floor Administration

5) The evaluator observed there was sign of water damage including brown staining at the ceiling of the conference room.


2nd floor Children In Patient (CIP 2)

6) The evaluator observed two of three men's patient common bathrooms had standard faucets that could be used as anchor points to tie to that can hold a person's weight.

During an interview at the same time as the observation the Director of Facilities stated that the patients go into the bathrooms unaccompanied. The Director of Facilities also stated that they ordered anti-ligature faucets, but that the standard faucets had not been replaced with the anti-ligature faucets because they ran out.

7) The evaluator observed the doctor's office had seven water damaged ceiling tiles.

8) The evaluator observed the dining room had a wall clock that was set 4 hours behind.

9) The evaluator observed that in room 212 there was peeling and missing paint at a wall, exposing unfinished porous plywood surfaces.

Housekeeping provided labels of products used to clean and disinfect the patient room walls. The products' labels, including the product used for terminal cleaning, indicated that the product was to be used on non-porous surfaces.


3rd floor Adult In Patient (AIP 1)

10) The evaluator observed there were fixtures that could be used as anchor points to tie to that can hold a person's weight throughout the unit; including exposed sink drain line and standard faucets.

The evaluator observed patient room 375's bathroom sink had exposed plumbing pipes that could be used as anchors.

During an interview at the same time as the observation the Director of Facilities acknowledged the exposed pipes, stated that the cover for the pipes was missing and the pipes should not be exposed.

The evaluator observed patient room bathrooms, including those in rooms 334, 339, 341, 348, 351, 352, 354, 357, and 362 had standard faucets that could be used as anchors.

During an interview the Director of Facilities stated that he had recently replaced the faucets thinking they were anti-ligature faucets because the manufacturer's literature stated the faucets were National Sanitation Foundation (NSF) safe for use in health facilities. The Director of Facilities also stated that the faucets could be replaced with anti-ligature faucets.

The evaluator's review of the manufacturer's literature provided by the Director of Facilities revealed that there was no indication in the literature that the faucets were ant-ligature.

11) The evaluator observed in room 356 the handle was missing from the hot water valve at the bathroom sink.

12) The evaluator observed at room 356 the top hinge of the corridor door was loose causing the door to drag against the floor.

13) The evaluator observed in rooms 341, 345 there was peeling and missing paint at a wall, exposing unfinished porous plywood surfaces.

Housekeeping provided labels of products used to clean and disinfect the patient room walls. The products' labels, including the product used for terminal cleaning, indicated that the product was to be used on non-porous surfaces.


3rd floor Adult In Patient (AIP 2)

14) The evaluator observed there were fixtures that could be used as anchor points to tie to that can hold a person's weight throughout the unit; including exposed sink drain line and standard faucets.

Patient room 313's bathroom sink had exposed plumbing pipes that could be used as anchors.

During an interview at the same time as the observation the Director of Facilities acknowledged the exposed pipes, stated that the cover for the pipes was missing and the pipes should not be exposed.

The evaluator observed patient room bathrooms, including those in rooms 312, 313 and 317 had standard faucets that could be used as anchors.

During an interview the Director of Facilities stated that he had recently replaced the faucets thinking they were anti-ligature faucets because the manufacturer's literature stated the faucets were NSF (National Sanitation Foundation) safe for use in health facilities. The Director of Facilities also stated that the faucets could be replaced with anti-ligature faucets.

Review of the manufacturer's literature provided by the Director of Facilities revealed that there was no indication in the literature that the faucets were ant-ligature.


22458

15. On 8/3/18 at 9:25 a.m., during an observation of the Treatment Room on the CIP Unit with RN 5, it was noted that the sink faucets did not work. RN 5 stated he was not aware the faucets were not working, and would notify the Maintenance Department.

On 7/31/18 at 3 p.m., during the initial tour, it was observed that the entrance door of the CIP Unit slammed shut during ingress and egress.

On 8/3/18 at 8:45 a.m., it was noted that the door again slammed shut.

On 8/3/18 at 2 p.m., during an interview, the Director of Materials Reprocessing stated he would have the door adjusted so that it would close quietly.

EMERGENCY GAS AND WATER

Tag No.: A0703

Based on document review and interview, the facility failed to provide documented evidence of a system to provide emergency water and failed to ensure an effective water management plan to be implemented in a widespread disaster by not providing documentation of the amount of emergency water needed by the facility.

This deficient practice had the potential to result in inadequate supply of drinking water and water for other purposes to all patients and staff during a disaster affecting the hospital and effectively meet the hydration and personal care needs of patients.

Finding:

On 8/2/18 at 1:18 p.m., the evaluator's review of the facility's disaster preparedness plan revealed there was no documented evidence that an assessment had been made determine the quantity of water needed for drinking, cleaning and food preparation.

At the same time as the plan review the Disaster Coordinator stated that the Dietary Director had the breakdown of the quantity of water needed.

The evaluator's review of the documents provided by the Dietary Director revealed that they also did not include an assessment had been made determine the quantity of water needed.

LIFE SAFETY FROM FIRE

Tag No.: A0709

Based on observation, interview and document review, the facility failed to ensure that the life safety from fire requirements were met.

The deficiency had the potential to not provide the minimum requirements of the Life Safety Code and referenced Codes and Standards.

Findings:

On 7/31/18 between 9 am and 11 am the following conditions existed at the facility.

Exterior Physical Plant

1) The evaluator observed the sight glass of the fuel gauge at the emergency generator's day tank was weathered opaque, so that the fuel level in the tank could not be read.

During an interview at the same time as the observation, the Mechanical Engineer stated that he did not know how much fuel was in the day tank because he could not read the fuel gauge.

During a second interview at the same time as the observation, the Director of Facilities stated that there was no other way to determine how much fuel was in the tank.

Basement

2) The evaluator observed the main electrical panel room was used to store three ceiling light fixtures, a ball, and a large 4 foot by 5 foot framed mirror. The items were located between the main electrical panel and the wall

3) The evaluator observed the main electrical panel room had 13 two-inch diameter penetration through the wall separating the main electrical panel room from the maintenance shop.

4) The evaluator observed the boiler room had a two-inch diameter penetration through a wall.

5) The evaluator observed the shop storage room corridor door had a missing lockset, creating a two-inch diameter penetration through the door.

During an interview at the same time as the observation, the Director of Facilities stated that the penetration through the door was caused by the removal of a lockset, that he did not know who removed or when it was removed, and that the penetration should not be there.

6) The evaluator observed that in the fan room there was a fire extinguisher that was being hung by the base its hose onto a bracket.

During an interview at the same time as the observation, the Director of Facilities acknowledged that the extinguisher was incorrectly placed in a manner that could damage the hose of the extinguisher.

7) The evaluator observed that in the medical records room, the second exit door was obstructed from fully opening by a shredding bin, a storage bin and a wire basket.

During an interview at the same time as the observation, the Director of Facilities acknowledged that the exit door was obstructed from closing.

8) The evaluator observed that in the medical records room an exit sign was obstructed from view from the occupied center of the room. The sing was obstructed by file cabinets.

9) The evaluator observed the kitchen storage room had items store to the height of the ceiling, bypassing the required 18 inch height clearance between the bottom of the sprinkler head deflector and the top of storage.

10) The evaluator observed that at the corridor wall across from elevators 1 and 2, there was broken electrical cover plate at the wall mounted electrical receptacle.

11) The evaluator observed the fire extinguisher and hose cabinet located at the corridor wall next to elevators 1 and 2, was missing the handle that unlatches the cabinet door to access the fire extinguisher and hose.

On 8/1/18 between 8:30 am and 2:30 pm the following conditions existed at the facility.

1st Floor Children Out Patient (COP)

12) The evaluator observed that at the COP waiting area there was no directional exit sign.

During an interview at the same time as the observation, the Director of Facilities stated a directional exit sign would be placed.

1st Floor Kitchen

13) The evaluator observed eight of nine blow off caps were not placed on the nozzles of the suppression system located above the cooking range and deep fryer.

During an interview at the same time as the observation, the Director of Facilities acknowledged the caps needed to be placed on the nozzles.

14) The evaluator observed one of one blow off cap was not placed on the nozzle of the suppression system located above the cooking area.

1st Floor Administration

15) The evaluator observed that in the room identified as Clinic by a paper sign posted on the door there was one of six oxygen cylinder stored unsecured standing on the floor.

During an interview at the same time as the observation, the Director of Facilities stated an oxygen storage rack would be obtained.

16) The evaluator observed that in the room identified as Clinic by a paper sign posted on the door there were 5 oxygen cylinders stored together and one cylinder on a crash cart without signage identifying which cylinders were empty and which were full.

During an interview at the same time as the observation, the Director of Facilities acknowledged there was no signage, and stated that the crash cart was not functioning.

2nd Floor Administration

17) The evaluator observed in the conference room there was daisy chaining of extension cords by having a power strip that was connected to an extension cord that in turn was connected to a second power strip that was connected to a wall mounted electrical receptacle.

18) The evaluator observed that in the Information Technology (IT) room there were seven 1 inch diameter penetrations through the ceiling of the server room and one 1 inch by 2 inch penetration in the IT office.

2nd Floor Mezzanine

19) The evaluator observed the smoke barrier wall above the double doors between the elevator and the children hospital had two penetrations.

During an interview at the same time as the observation, the Director of Facilities acknowledged the penetration.

2nd floor Children In Patient (CIP 2)

20) The evaluator observed the corridor door of room 212 failed to hold closed when shut.

During an interview at the same time as the observation, the Director of Facilities stated the door failed to hold closed because the strike plate was misaligned.

21) The evaluator observed a wall was constructed of plywood in non-sprinklered room 212.

3rd floor Adult In Patient (AIP 1)

22) The evaluator observed there was a drop down fire door that would separate a nurses station from the charting room. There was no label on or around the door of inspection and testing of the door.

During an interview at the same time as the observation, the Director of Facilities stated there was documented record of the door's current inspection and test.

During document review there was no documented evidence presented of the door being inspected and tested.

23) The evaluator observed a wall was constructed of plywood in non-sprinklered room 341.

During an interview at the same time as the observation, the Director of Facilities stated that the drywall was replaced by plywood because the patients damage the drywall.

24) The evaluator observed a wall was constructed of plywood in non-sprinklered room 345.

25) The evaluator observed the corridor door of room 345 was missing.

During an interview at the same time as the observation, the Director of Facilities stated that the door was removed about one week ago because it was broken and that they were waiting for the replacement door.

26) The evaluator observed the corridor door of room 347, a treatment room, was a Dutch door that did have an astragal where the top and bottom leaves meet.

27) The evaluator observed the fire barrier wall above the cross corridor doors near room 348 had a 1 inch diameter penetration.

During an interview at the same time as the observation, the Director of Facilities identified the wall as a fire barrier wall.

28) The evaluator observed there was a drop down fire door that would separate nurses station one from the day room. There was no label on or around the door of inspection and testing of the door.

During an interview at the same time as the observation the Director of Facilities stated there was documented record of the door's current inspection and test.

During document review there was no documented evidence presented of the door being inspected and tested.

29) The evaluator observed there was a drop down fire door that would separate nurses station one from the day room. The fire rating plate on the door was painted over and illegible.

30) The evaluator observed the corridor door of room 352 failed to hold closed when shut.

During an interview at the same time as the observation, the Director of Facilities stated that the door failed to hold because the wrong type of strike plate was installed.

3rd floor Adult In Patient (AIP 2)

31) The evaluator observed the smoke barrier wall above the ceiling separating the corridor from room 325, an office, had a 1 inch diameter penetration.

During an interview at the same time as the observation, the Director of Facilities stated he could see the penetration.

3rd floor Adult Out Patient (AOP)

32) The evaluator observed that in doctor office 8 there was daisy chaining of extension cords by having an extension cord connected to a power strip that was connected to a wall mounted electrical receptacle.

33) The evaluator observed that in a social worker office there was an extension cord that was passed under the carpet across a threshold that was connected to a wall mounted electrical receptacle.

Document Review

On 8/2/18 at 9:50 a.m., document review revealed the following:

34) Document review by the evaluator revealed there was no documented evidence of sensitivity of the smoke detectors.

35) Document review by the evaluator revealed there was no documented evidence that the transfer switch was being inspected and tested.

During an interview at the same time as the document review, the Director of Facilities stated that the transfer switch was being tested monthly but that there is no documented evidence because the in house engineer was using the wrong form in the log that does not have a place for documenting the test.

36) Document review by the evaluator revealed there was no documented evidence that transfer time of emergency power was being tested.

During an interview at the same time as the document review, the Director of Facilities stated that the transfer time was between 8 to 10 seconds but that the transfer times were not being documented because there was no place on the log to document the times, and that the log would be recreated to include a place to enter transfer times.

37) Document review by the evaluator revealed there was no documented evidence that smoking regulations were adopted for smoking by patients, including smoking prohibited areas, designated smoking areas, which patients are prohibited to smoke, which patients are allowed to smoke, supervision of patients smoking, providing ashtrays of noncombustible material and safe design in all areas where smoking is permitted, and providing metal containers with self-closing cover devices into which ashtrays can be emptied readily available to all areas where smoking is permitted.

Review of the Smoke Free Environment Policy and Procedure, numbered 7080.7577.53 with a revised date of 3/1/2008, indicated that the purpose of the policy was to provide guidelines for governing a smoke free work environment, and that the scope of the policy was applicable to all employees. The policy had no indications in it for smoking by patients.

During an interview at the same time as the document review, the Director of Facilities stated that there is therapy smoking by patients at the AIP 1 smoking patio.

FACILITIES, SUPPLIES, EQUIPMENT MAINTENANCE

Tag No.: A0724

Based on observation, and staff interviews, the hospital failed to ensure facilities and food service equipment were maintained to an acceptable level of safety for patients and staff; failed to maintain equipment to ensure safety and quality by not maintaining eyewashes, light diffusers, and light shields; failed to ensure the water faucet was working in the handwashing sink located inside the medication storage area at the children inpatient nursing unit (CIP); failed to ensure there was no white mineral deposit in the medication room in the Adult InPatient area 1 (AIP1).

The deficiencies had the potential to hinder the practice of infection control; had the potential of any person that may have their eyes exposed to injurious materials to not have quick drenching or flushing of the eyes with water delivered at a tepid temperature, and for potential for shattered glass from lighting tubes and bulbs being contained.

Findings:

1. During the tour of the kitchen on July 31, 2018 starting at 11:10 AM, during hand washing, the surveyor found the water temperature to be uncomfortably warm. There was no signage warning of the high water temperature. On August 1, 2018 at 10:20 AM during hand washing, the water temperature once again felt uncomfortably warm. In an interview with the DFS on August 1, 2018 at 11:00 AM about the high water temperature, DFS stated he was not aware that the water temperature was high and acknowledged the water temperature would not allow food service staff to wash their hands long enough (20 seconds) as recommended. The DFS stated one of the registered dietitians (RD 1) had requested that water temperature be increased and so it was turned up by the facilities department.

A temperature check of the water showed it as 126.1 degrees Fahrenheit (F). Warm water is more effective than cold water in removing the fatty soils encountered in kitchens. An adequate flow of warm water will cause soap to lather and aid in flushing soil quickly from the hands. High water temperature that makes hand washing uncomfortable may lead to poor handwashing practices by food employees. According to the 2017 Food Code Section 5-202.12 (A) "A handwashing sink shall be equipped to provide water at a temperature of least 100 degrees F through a mixing valve or combination faucet". ASTM Standards for testing the efficacy of handwashing formulations specify a water temperature of 100 to 108°F. American Society for Testing and Materials (ASTM) , is an international standards organization that develops and publishes voluntary consensus technical standards for a wide range of materials, products, systems, and services.

Also attached to the faucet was an eye wash station. Higher water temperatures are harmful to the eyes and can enhance chemical interaction with the skin and eyes. The American National Standards Institute (ANSI) and the International Safety Equipment Association (ISEA) developed the American National Standard for Emergency Eyewash and shower Equipment standards for the use, installation, operation and maintenance for emergency eye wash and shower equipment (ANSI/ISEA z358.1-2014) . ANSI/ISEA requirements for installation for plumbed emergency eye wash station include the eye wash station head "deliver ....tepid flushing water for 15 minutes". According to ANSI/ISEA Z358.1-2014, "tepid" is defined as a flushing fluid temperature conducive to promoting a minimum 15-minute irrigation period. A suitable range is 60 to 100 degrees Fahrenheit." Higher water temperatures are harmful to the eyes and can enhance chemical interaction with the skin and eyes. The tepid water is also to encourage compliance with the 15-minute irrigation period.

2. At 2:15 PM on July 31, 2018, the faucet in the 2-compartment sink was leaking hot water in the sanitizing compartment water. The constant dripping of the hot water into the solution had the potential to dilute the concentration, thereby making it ineffective. Sanitization of food service equipment and utensils removes (kills) potential disease causing organisms on the surface of the equipment.

The facilities manager (FM) who was present during the observation, stated he was unaware but would repair the faucet by the next day. Observation on August 3, 2108 at 2:50 PM, showed the faucet had not been repaired.

3. At 3:47 PM on August 1, 2018, the temperature gauge for the dish machine was broken. The glass on the dial was cracked, chipped and temperature was stuck at 140 degrees F for both the wash and rinse cycles. The FSM flicked the temperature gauge with her finger, which moved the thermometer from 140 to 108 degrees F. The temperature gauge did not move after several wash cycles were observed. The manufacturer's recommended minimum water temperature for the machine for both wash and rinse cycles was 120 degrees F.

Food service worker (FSW 3) who operated the machine stated the water temperature of machine is checked using a hand-held food thermometer. The temperatures are recorded while watching and listening to the different cycles. The FSM stated in a concurrent observation that she could not remember how long the thermometer had broken and when the food service staff started inserting a food thermometer in the water well to check water temperatures. The process was unsafe due an increased the risk of burn as the water splashed as it was flowing and circulating the well.

4. There was water spewing out leaking from the faucet in the chemical storage/janitorial area outside the kitchen. Attached to the faucet was a two paired hose bib connection, the hoses were red and black in color. A hose bib(b) is a "threaded faucet also known as a wall hydrant". The end of the red hose was inside a blue bucket on the floor with a dark brown solution, with bubbles resembling soap or detergent. The connection did not have an anti-siphon or back-flow prevention device. There was a significant build- up of a brown colored substance on the rack adjacent to the faucet, resembling rust. There was a similar colored substance on the horizontal bracket that held the water pipe to keep the faucet in place. The presence of rust could be an indication of the presence continued moisture in the area.

According to the 2017 Food Code Section 5-203.14. "a plumbing system shall be installed to preclude backflow of a solid, liquid, or gas contaminant into the water supply system at each point of use at the food establishment, including on a hose bibb if a hose is attached .... and backflow prevention is required by law, by: (a) providing an air gap as specified under § 5-202.13 or (b) installing an approved backflow prevention device ..."

The facilities director in an interview on August 1, 2018 starting at 3:50 PM indicated he was not aware of the leaking of the faucet. In an interview with the FSD on August 1, 2018 starting at 4: 00 PM, the FSD indicated he made reports to the facilities department about the various equipment that needed repairs. The FSD stated the reports were in form of email but was unable to provide evidence of the reports because he "does not keep email".

5. There were several light fixtures in the dish room had broken. This could be a source of cross-contamination of the clean dishes stored in the area.

Section 6-202.11 (A) "light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service and single-use articles".


16281


5. Basement

On 7/31/18 at 10:27 a.m., the evaluator observed that in the boiler room located in the basement, there was no documented evidence of testing of the eyewash station. During the same observation the Director of Facilities had difficulty operating the pull knob to activate the eyewash station. At first on a trickle of water ran down the sides of the eyewash nozzles, then after a delay and struggling with the pull knob the Director of Facility was able to pull the knob to activate water flow from the nozzles of the eyewash station.

During an interview at the same time as the observation, the Director of Facilities acknowledged the pull knob was stuck, and stated that the eyewash was supposed to be tested weekly, but that it had not been tested.

On 8/1/18 between 8:30 a.m. and 2:30 p.m. the following conditions existed in the facility.

6. 1st floor kitchen

The evaluator observed there was no documented evidence of testing of the eyewash station in the kitchen. When the Director of Facilities activated water flow from the nozzles of the eyewash station it was observed that the water flow was toward the wall and away from the person activating the eyewash.

Closer observation revealed the water source was controlled by a single sensor valve and not by individual hot and cold water valves. At this time the temperature of the water was tested with a result of 120 oF (degrees Fahrenheit).

During an interview at the same time as the observation, the Director of Facilities acknowledged the flow of the water was in the wrong direction, that the water temperature was 120 oF, and stated that there was no testing of the eyewash, that the eyewash would be removed because the water was too hot, and that a bottle eyewash would replace it.

7. The evaluator observed two of six ceiling light fixtures in the food preparation and cooking area had cracked diffusers/covers, and a 6 inch by 2 inch section was missing from one of the diffusers/covers.

During an interview the Director of Facilities stated that ceiling light fixtures were going to be replaced

8. The evaluator observed three of six ceiling light fixtures in the dishwashing area were missing diffusers/covers exposing the glass tubes. No other form of light shields were observed at the light fixtures.

9. The evaluator observed one of two light shields was missing in the reach in refrigerator freezer unit at the kitchen dry storage area.


28851

10. On 8/1/2018 at around 4:10 p.m. during an inspection of the medication storage area (med room) at the CIP, there was a sink to the right of the entrance of the med room. The surveyor attempted to turn the faucets on; however, the faucet produced a tiny stream of water at maximum turn. The director of pharmacy (DOP) acknowledged the faucet was not functioning properly.

During a concurrent interview, the unit charge nurse indicated the nurses had been using other sinks located elsewhere in the unit for an unknown amount of time.


36329

11. During a tour of the facility's medication room on 7/31/2018 at 10:00 AM on the Adult InPatient area 1 (AIP1), the faucet appeared to have white mineral deposit on the end of the spout; there was no hot available from this faucet.

At that time, the Charge Nurse acknowledged there was no hot water available from this faucet and the spout did appear crusted with some kind of mineral.

VENTILATION, LIGHT, TEMPERATURE CONTROLS

Tag No.: A0726

Based on observation, interview, and record review, the hospital failed to ensure there were temperature monitoring devices installed in the medication storage and preparation areas, such as medication rooms at the nursing units; and failed to ensure that lighting fixtures in the kitchen were maintained.

This deficient practice had a potential affecting the integrity, stability, and/or potency of the products.

Findings:

a. During an inspection of the medication room inside the adult inpatient station 1 (AIP-1) on 7/31/2018 at 12:55 p.m., the director of pharmacy (DOP) confirmed there was no temperature monitoring device for the ambient temperature.

During an interview on 8/1/2018 at 11:16 a.m., the DOP there was no documented daily monitoring of the ambient temperature inside the medication storage areas located at the nursing units; there were four such areas excluding the inpatient pharmacy.

Review of the hospital policy and procedure, Temperatures: Storage, last reviewed 4/2018, indicated all drugs shall be stored at appropriate temperatures that do not exceed manufacturer's recommendation; the policy also indicated a controlled room temperature range.

Review of another hospital policy and procedure, Storage of Medications, last reviewed 4/2018, indicated "Drugs shall be stored under the proper conditions of sanitation, temperature, light, moisture, ventilation,..."


16281


b. On 8/1/18 between 8:30 a.m. and 2:30 p.m. the following conditions existed in the facility.

3rd floor Pharmacy

1) The evaluator observed that in medication rooms, including the medication rooms at Adult In Patient (AIP) 1 and Children In Patient (CIP), there were tube type refrigerator/freezer thermometers with a -18 to 84 oF (degrees Fahrenheit) range in use to measure the ambient temperatures of the rooms.

The evaluator observed that in the Pharmacy there was a dial type refrigerator thermometer with a -20 to 82 oF range in use to measure ambient temperature of the room.

The evaluator's review of policy and procedure number 8390.09.04 for pharmacy temperature storage revised 10/2014 defined room temperature and controlled room temperature as a temperature held between 59 and 86 oF.

The temperature measuring instruments used to measure the ambient room temperatures in the medication rooms and the pharmacy did not have the range necessary to determine if the ambient room temperature was out of range.

During an interview at the same time as the observations, the Director of Facilities stated that the ambient temperatures of the medication storage rooms are monitored daily by use of a laser temperature gun and recorded in the temperature log.

On 8/2/18 at 11:09 a.m., the evaluator's review of the weekly temperature log book revealed that ambient room temperatures were monitored weekly not daily, and that the temperatures were monitored at the 3rd floor AIP 1 and 2 patient rooms and (nurses) stations' 1 and 2. There was no documentation that temperatures were monitored at the 2nd floor CIP including the CIP medication room and the Pharmacy at 3rd floor Outpatient.

1st floor kitchen

2) The evaluator observed that one of six ceiling light fixtures in the dishwashing area was not providing light.

3) The evaluator observed one of six ceiling light fixtures in the food preparation and cooking area was not providing light.

4) The evaluator observed there was no light in the reach in refrigerator freezer at the kitchen dry storage area. Closer observation revealed one of two light bulb was missing and one of two light bulb was burned out.

During an interview at the same time as the observation, the Dietary Director stated that the bulbs would be replaced.

INFECTION CONTROL PROFESSIONAL

Tag No.: A0748

Based on interview and record review, the facility failed to designate a qualified infection control officer (ICO) verified by experience, training, education, or certification.

Findings:

During a conversation with ICO on 7/31/2018 at 11:20 AM, he stated that he was a Licensed Vocational Nurse (LVN) who had only been working at this facility for approximately 6 months; he affirmed he previously worked at this facility as a case manager. He continued on to say that as of this date he had not received any training or possess any training in infection control. When asked about the facility's policy on staff immunizations, he stated that he was not sure of PPD (a test used to diagnose latent tuberculosis, purified protein derivative) requirements and that the facility was currently developing its policy regarding influenza immunization. Lastly, he stated the facility was still studying quality indicators to be included in its QAPI program.

A review of the personnel file of ICO, indicated no evidence of training in infection control.

INFECTION CONTROL PROGRAM

Tag No.: A0749

Based on observation, review of facility documents, manufacturer's instructions and staff interviews, the hospital failed to develop a system to prevent infections when it failed to monitor the cooling of several leftover or over-produced time temperature control for safety (TCS) food items (formerly potentially hazardous food). The food items including rice, chicken salad, gravy, potatoes and beans had been stored in the refrigerator from about twenty- four hours to as many as 19 days. The size of the food containers in which the food were stored varied from as little as a few servings to a large 6- quart container (about 8 inches tall) of cooked Spanish rice filled all the way to the brim. The facility did not have a system in place to ensure food was cooled to the appropriate temperature within the recommended time-frames. The Food Code provision for cooling "The food danger zone refers to temperatures above 41 degrees F and below 135 degrees F that allow the rapid growth of disease causing microorganisms that can cause foodborne illness. Foods held in the danger zone for more than .....6 hours ....may cause a foodborne illness if consumed". (Centers for Medicare and Medicaid, State Operations Manual)

The facility did not monitor temperatures or utilize a cooling log to document the process. The director of Food service (DFS) responded to the surveyor on 7/31/18 at 11:46 AM about the lack of monitoring of leftover items. The staff failed to take the appropriate corrective actions including but not limited to discarding the items and ensuring temperature monitoring was taking place. More leftover or over-produced items were found in the refrigerator the following day on August 1, 2018 at 10:25 am. In addition, on August 1, 2018 at 11:30 AM, staff reheated a leftover chicken dish from the day before that was not monitored for proper cooling and attempted to serve to staff in the cafeteria before the surveyor stopped it from being served.

The director of the food service operation did not meet state educational requirements for the job including completion of a food safety course for managers. Only two of the ten employees had completed a food safety course contrary to state law that requires all food service works to complete a food handler's course. The food service manager who had completed a food safety course for managers and one of the cooks who had a food handler's card were the two employees who were compliant.

The failure of the hospital to monitor proper cooling of food, lack of staff knowledge and system to implement the process and the lack of corrective action on the part of the DFS after it had been identified the day before created an immediate jeopardy (IJ) situation that had the potential to result in food borne illness. This had the potential to cause food borne illness including death to all 33 patients and staff.

Immediate jeopardy was declared on 08/2/18 at 2:20 PM. The survey team informed the chief nursing officer of the immediate jeopardy situation. On 08/2/18 at 5:40 PM, the chief nursing officer provided an acceptable plan of action. The actions to remove the immediate jeopardy situation included discarding any leftover items, educating staff on discarding all leftover items after all meals are served without exception and staff training on food safety and bacterial growth.

The immediate jeopardy was abated (reduced in amount, degree or intensity) on August 3, 2018 at 3:05 PM when the facility was able to demonstrate knowledge of proper cooling of food, non-use of leftover items.

The facility also failed to supply a hospital wide infection control plan.

In addition, the facility failed to provide a safe and sanitary environment for patients, by failing to ensure the glucometer (a machine that checks the amount of sugar in the blood stream) was disinfected according to manufacturer's instructions. This failure had the potential to result in cross-contamination between patients.

Findings:

1. Inside the walk in refrigerator on July 31 at 11:45 AM, there were several containers of food that were leftover food from previous meals stored on the second shelf. There was a container of cooked rice dated 7/30, a container of ham also labeled 7/30. There was gravy in a container dated 7/29, a container labeled meatballs dated 7/26. There was also a large 6- quart container labeled Spanish rice filled almost to the brim.

The observation was shared with DFS on July 11 at 11:48 AM. The surveyor requested for cooling logs to evaluate whether the items were cooled appropriately. DFS stated in the interview on July 31, 2018 at 11:48 AM, there were no cooling logs because the hospital does not save leftover items.

On August 1, 2018 at 10:26 AM, the same gravy container dated 7/29, observed the day before in the refrigerator was on the shelf in the refrigerator. There were other leftover items observed stored on the top shelf in the refrigerator. There was sally mashed potato dated 7/26/18, diced potato dated 7/12/18, beans dated 7/23/18, red potatoes dated 7/12/18, rice dated 7/29/18 another container of rice dated 7/30, garlic potatoes 7/26. The surveyor shared the observation with the DFS. The DFS stated on August 1, 2018 at 10:28 AM, the kitchen's priority was" to get breakfast and lunch out". DFS then directed Cook 1 to dispose of the leftover items. Cook 1 stated in the concurrent interview and observation on August 1, 2018 at 10:29 AM, he believed there was a 3- day grace period to use leftover items and they do not monitor or use any logs.

On August 1, 2018 at 11: 35 AM, there was a stainless steel pan in the oven. The Food Service manager stated item in the oven was the smothered chicken from the day before was being reheated for the cafeteria. FSM explained the entrée for the day was pork chop and the chicken which had been stored in the refrigerator was the substitute. The FSM stated there was no cooling log or monitoring of temperatures of the chicken dish completed.

A review of the hospital policy and procedure titled, "Receiving Food and Supplies" dated 4/26/17 under the subheading "Handling over-produced food, leftover food and extra food" states "over produced food which has not been on the steam table, may be stored for later use. For example, 10 extra portions of chicken may be wrapped, labeled, dated and refrigerated, after cooking is completed. Over-produced refrigerated foods must be used within 48 hours of the original cooking time; .....". The hospital policy did not guide the staff to monitor cooling leftover or over produced food items appropriately.

There were other deficient practices identified during the survey for both campus related to improper food storage, improper food cooling, poor ice machine cleaning practices and general uncleanliness of the foodservice area, storage and preparation of food that could result in food poisoning and food borne illness, improper dish washing practices.

2. On July 31, 2018 at 11;45 AM, there were three boxes of coleslaw dated 7/3/18 stored in the refrigerator. All three boxes had manufacturer's use by date of 7/23/18. There was also a 20 lb. box of peas stored on the lower shelf in the refrigerator dated 7/20/18 with manufacturer's instructions to "Keep frozen until ready to cook". The DFS stated in an interview on July 31 at 11:47 am, he was not sure why the box of peas was in the refrigerator and not in the freezer.

3. There was a black substance observed along the length and width of walls on the caulking that sealed the stainless steel to the wall, on the grout lines of the wall tiles. The black substance resembled mildew (mold). The presence of molds could result in the contamination of stored food products and allergic reactions in patients, visitors and patients who are allergic to mold. The hospital did not ensure there was an effective system to identify unsanitary conditions in the dishwashing room. The kitchen staff did not identify a black substance on the walls in the dish machine area. These failures had the potential to affect all kitchen staff, other hospital staff, visitors and 33 patients that were admitted to the hospital through cross contamination of surfaces and air transmission.

4. During meal observation on August 1, 2018 at 12:10 PM the Adult in patient unit, Patient 38 had asked for ice. The Mental Health Technician (MHT) who supervised the patients stated there was no ice available. Patient 38 continued to ask for ice stating "ice, ice, baby" with the request for ice getting louder. MHT scooped ice from the container that held the frozen dessert and provided to Patient 38. This ice could have been a potential source of contamination.

5. In an interview with the group of food service workers on August 3, 2018 at 2:55 PM, a random FSW explained that the hospital does not provide them with uniforms and the expectation is that if they need aprons they will have to purchase those themselves. FSW 3 who had an apron stated in an interview on August 1, 2018 at 2:15 PM, that he purchased the apron he had and takes it home to launder. Cook 2 who was also wearing an apron stated in an interview on August 1, 2018 at 10:47 AM, that the hospital did not provide him with the apron. Cook 2 stated that the plastic aprons melt when he gets close to the stove and heating equipment. The FSM who was present during the interview stated the hospital was" between vendors" and are currently not being provided with aprons. The Director of Food Services in an interview on August 3, 2018 at 2:25 PM, stated the hospital does not provide uniform or aprons.

A review of the contracts between the previous and current laundry services provider, indicated that Contractor 1, (previous provider) provided kitchen towels, aprons, chef's coat, cook shirts and pants as part of the service (Exhibit B). A review of the contract for Contractor 2, (current provider) did not indicate if similar items were provided. There was a list of items as part of the contract but no aprons or kitchen towels were on the list. In an interview with the Laundry Supervisor (LS) on August 3, 2018 at 3:00 PM, LS acknowledged that the current laundry services did not provide aprons.

The lack of aprons for food service staff exposed the patients to possible cross contamination of food from clothing. Dirty clothing may harbor diseases that are transmissible through food. Food employees who inadvertently touch their dirty clothing may contaminate their hands. This could result in contamination of the food being prepared. Food may also be contaminated through direct contact with dirty clothing. (Food Code Annex)

According to the 2017 Food Code Annex "All of the following control measures should be implemented regardless of the food preparation process used: ... ... Prevention of cross-contamination of ready-to-eat food or clean and sanitized food-contact surfaces with soiled cutting boards, utensils, aprons, etc., or raw animal foods.

6. There was water spewing out leaking from the faucet in the chemical storage/janitorial area outside the kitchen. Attached to the faucet was a two paired hose bib connection, the hoses were red and black in color. A hose bib(b) is a "threaded faucet also known as a wall hydrant". The end of the red hose was inside a blue bucket on the floor with a dark brown solution, with bubbles resembling soap or detergent. The connection did not have an anti-siphon or back-flow prevention device.
The lack of an anti-siphon or back flow device created a condition that could lead to the potential contamination of the hospital water supply with the soapy contaminated visibly dirty water in the bucket.

7. The hand washing sink in the kitchen was located less than 6 inches from the drain board of the food preparation sink. There was no installed splash- guard to prevent soap or water from hands being washed from contaminating prepared food on the food preparation sink next to it.


36329


8. During a conversation with ICO 7/31/2018 at 11:20 AM, he stated he was not sure the facility had an infection control (IC) plan but he had only been working at the facility for a few months. When asked what his duties up to this time were, he stated that he primarily had been building reports regarding patient infectious diseases developed or reported during their stays. He announced he would look for the IC plan which he believed the facility had.

No IC plan was presented to surveyors by the end of the survey on 8/3/2018.


22458


9. On 7/31/18 at 9:35 a.m., during a tour of the Adult Inpatient Unit (AIP) 2, Staff 8 was asked how she cleans the glucometer, she stated she sometimes cleans it with alcohol wipes.

On 7/31/18 at 10:40 a.m., Staff 9 stated the glucometer is cleaned using alcohol or Sani-Cloth wipes.

A review of the online manufacturer's instructions for cleaning the [Brand Name] Glucometer indicated the glucometer should be cleaned with several brands of disinfectant wipes, such as Super Sani-Cloth Germical Wipes and CaviWipes.

SOCIAL SERVICES RECORDS PROVIDE ASSESSMENT OF HOME PLANS

Tag No.: B0108

Based on document review and staff interview, the facility failed to ensure that the Psychosocial Assessments for eight (8) out of eight (8) active sample patients (1, 2, 3, 4, 5, 6, 7, and 8) included anticipated Social Work roles in treatment. As a result, critical and professional patient psychosocial information necessary for informed treatment planning decisions was not available to the treatment teams.

Findings include:

A. Record Review

1. Patient 1 was admitted for "danger to others and gravely disabled" on 6/25/18. The Psychosocial Assessment completed on 6/25/18 did not identify anticipated roles for social work staff in formulating interventions for inpatient treatment.

2. Patient 2 was admitted for "danger to others and gravely disabled" on 7/13/18. The Psychosocial Assessment completed on 7/13/18 did not identify anticipated roles for social work staff in formulating interventions for inpatient treatment.

3. Patient 3 was admitted for "gravely disabled" on 12/13/17. The Psychosocial Assessment completed on 12/14/17 did not identify anticipated roles for social work staff in formulating interventions for inpatient treatment.

4. Patient 4 was admitted for "danger to self and danger to others" on 7/7/18. The Psychosocial Assessment completed on 7/10/18 did not identify anticipated roles for social work staff in formulating interventions for inpatient treatment.

5. Patient 5 was admitted for "danger to others " on 7/21/18. The Psychosocial Assessment completed on 7/21/18 did not identify anticipated roles for social work staff in formulating interventions for inpatient treatment.

6. Patient 6 was admitted for " gravely disabled" on 7/8/18. The Psychosocial Assessment completed on 7/9/18 did not identify anticipated roles for social work staff in formulating interventions for inpatient treatment.

7. Patient 7 was admitted for "danger to self and danger to others" on 7/23/18. The Psychosocial Assessment completed on 7/24/18 did not identify anticipated roles for social work staff in formulating interventions for inpatient treatment.

8. Patient 8 was admitted for "danger to self and danger to others" on 7/25/18. The Psychosocial Assessment completed on 7/26/18 did not identify anticipated roles for social work staff in formulating interventions for inpatient treatment.

B. Staff Interview

In a meeting with the acting Director of Social Services on 7/31/18 at 1:00 p.m., the above deficiencies were reviewed. She agreed with the above findings and further stated, "Social work has a critical role in the treatment of patients."

PSYCHIATRIC EVALUATION

Tag No.: B0110

Based on record review and interview, the facility failed to:

I. Provide comprehensive and complete psychiatric evaluations. Specifically, the psychiatric evaluations had no assessments that included memory functioning for six (6) of eight (8) active sample patients (2, 3, 5, 6, 7 and 8). This deficiency compromises the database from which diagnoses are determined and from which changes in response to treatment interventions may be measured.

Findings include:

I. Lack of timely psychiatric evaluations

A. Record Review

1. Patient N1 was admitted on 11/2/17 at 3:30 p.m. for "Psychosis NOS [not otherwise specified] and danger to self." The Root Cause Analysis (undated) stated, "Client was brought in by [spouse] to urgent care clinic for psychiatric evaluation due to increasingly unpredictable behavior. Client stated hearing voices telling [him/her] to harm [himself/herself] and [spouse] reported client was found with a knife attempting to [self-mutilate his/her genitals]." There was no psychiatric assessment completed prior to the patient being taken by police for allegations of murder on the evening of 11/2/17.

2. Patient N2 was admitted on 11/2/17 at 4:00 p.m. for Unspecified Mood Disorder and danger to self." The Root Cause Analysis (undated) stated, "[S/he] expressed feeling depressed, felt like hurting [himself/herself] with plans to stab [himself/herself] with pencils." There was no psychiatric assessment completed prior to the patient being transferred to another facility on 11/3/17 at 2:30 p.m.

B. Interview

On 8/1/18 at 10:15 a.m., the Medical Director agreed that the psychiatric assessments were not completed and that the facility does not have psychiatrists on duty after hours.

II. Lack of comprehensive and complete psychiatric evaluations

A. Record Review

1. Patient 2's Psychiatric Evaluation (dated 7/14/18) did not include any assessment of the patient's memory.

2. Patient 3's Psychiatric Evaluation (dated 12/14/17) did not include any assessment of the patient's memory.

3. Patient 5's Psychiatric Evaluation (dated 7/22/17) did not include any assessment of the patient's memory.

4. Patient 6's Psychiatric Evaluation (dated 7/8/17) did not include any assessment of the patient's memory.

5. Patient 7's Psychiatric Evaluation (dated 7/24/17) did not include any assessment of the patient's memory.

6. Patient 8's Psychiatric Evaluation (dated 7/25/17) did not include any assessment of the patient's memory.

B. Interview

On 7/31/18 at 10:10 a.m., the Medical Director agreed that memory was not assessed in the Psychiatric Evaluation.

TREATMENT DOCUMENTED TO ASSURE ACTIVE THERAPEUTIC EFFORTS

Tag No.: B0125

Based on record review, document review, and interviews, the facility failed to provide adequate treatment and monitoring for one (1) of three (3) discharged patients (N1) who subsequently assaulted and murdered his/her roommate (E1). In addition, the facility failed to ensure that an adequate root cause analysis and a prompt review by their Morbidity and Mortality Board were completed to address the circumstances surrounding this event and to implement corrective actions. Without taking appropriate and immediate actions to mitigate risks and prevent future recurrence of unsafe practices, the health and safety of all newly admitted patients may be jeopardized.

Findings include:

A. Record Review

Patient N1 was admitted on 11/2/17 at 3:30 p.m. for "Psychosis NOS and danger to self." The undated Root Cause Analysis stated "Client was brought in by [spouse] to urgent care clinic for psychiatric evaluation due to increasingly unpredictable behavior. Client stated hearing voices telling [him/her] to harm [himself/herself] and [spouse] reported client was found with a knife attempting to ... [self-mutilate his/her genitals]." There was not a psychiatric assessment completed prior to the patient being taken by police for allegations of murder the evening of 11/2/17. In addition, there was a significant discrepancy in how often N1 was to be monitored by staff. The nursing assessment noted 30 minute checks, the rounds sheet indicated that the patient was monitored every 20 minutes, and the facility policy stated that all patients were to be monitored every 15 minutes. Furthermore, there was not a progress note or discharge summary documenting the time of discharge to the police. These failures delayed the treatment of acute symptoms with psychotropic medication and assessment of the patient condition by a qualified psychiatrist. In fact, the patient was not evaluated by a psychiatrist during the hospital stay and no antipsychotic medications were ordered.

B. Document Review

1. The facility provided the surveyors with a copy of the undated Root Cause Analysis titled "Sentinel Event." This document did not include dates when meetings occurred, analysis of contributing factors such as human and environmental. There was no mention of a failure to monitor, evaluate or medicate the patients in the document. Therefore, there were no corrective actions identified to address these issues to prevent further reoccurrences.

2. The medical staff did not review this death and there were no minutes from the Mortality and
Morbidity Board as of August 1, 2018.

3. Patients N1 was placed on every 30-minute observation per the "RN's Mental Health Nursing History and Assessment" dated 11/2/17 at 5:00 p.m. However, there was no physician order denoting "Precautions" on the "Physician Admission Orders" dated 11/2/17 at 5:45 p.m. These orders were telephone orders and were not signed by a physician until 3/15/18. In addition, the patient, according to the rounds sheet, was monitored every 20 minutes. The facility policy, "Rounds for Patient Observation" and reviewed/revised 12/2017, stated, "Every patient must be seen/located by the staff member every fifteen minutes with documentation as to patient location/activity on the Rounds form according to the location code."

4. The facility did not have a Death Review Policy or Procedure and used the undated Sentential Event Procedure # 6009 [no date] which did not address homicides in the procedure. The procedure also did not address the management and review of expected and unexpected deaths by medical staff or mortality review board.

5. There were no documents to review to determine that the facility took actions to mitigate the risks to prevent recurrence.

C. Staff Interviews

1. On 8/1/18 at 10:15 a.m., the surveyors interviewed the CEO and Medical Director and they agreed that they had not taken actions to mitigate risk to the patient. The CEO explained he is trying to have the unit remodeled, replace the patient room doors with flexi glass windows but this has not been completed. Furthermore, the CEO reported he had not reviewed the root-cause-analysis. The CEO state, "Things could have been managed much better.

2. On 8/1/18 at 11:00 a.m., the surveyor interviewed the Director of Quality Improvement and he/she agreed the root-cause-analysis was vague and did not provide an in-depth analysis of the event including the analysis of contributing factors such as human and environmental.

3. On 8/1/18 at 10:00 a.m., the Director of Nursing stated, "You are correct. The observation documents do not agree with the policy."

RECORDS OF DISCHARGED PATIENTS INCLUDE DISCHARGE SUMMARY

Tag No.: B0133

Based on record review, document review, and interview, the facility failed to ensure that discharge summaries were dictated, transcribed and signed within 14 days of discharge for three (3) of five (5) sample discharged patients (D1, D3, and D4) and for two (2) of two (2) added discharged patients (N1 and N2) and one (1) death (E1). This deficiency results in a failure to communicate in a timely manner final diagnosis, current medications, the course of treatment, summary of relevant labs and testing, anticipated problems and discharge plan with outpatient providers.

Findings include:

A. Record Review

1. D1's discharge summary (discharge dated 6/11/18 with discharge summary dated 6/29/11) was not completed within 14 days and was not signed by the physician.

2. D3's discharge summary (discharge dated 6/15/18 with discharge summary dated 7/2/18) was not completed within 14 days and was not signed by the physician.

3. D4's discharge summary (discharge dated 6/17/18 with discharge summary dated 7/2/18) was not completed within 14 days and was not signed by the physician.

4. N1 (discharged 11/2/17) had no discharge summary.

5. N2 (discharged 11/3/17) had no discharge summary.

6. E1 (death 11/2/17) had no discharge summary.

B. Document Review

An undated facility document titled "Discharge Summaries" stated, "Entire chart to be fully completed by 14 days from discharge." [Note: This document had no date.]

C. Interview

On 7/31/18 at 10:10 a.m., the Medical Director agreed that the discharge summaries were missing, late or not signed by the physician. He stated, "This should have been done."

NUM/QUAL OF MD/DO ADEQUATE TO PROVIDE PSYCH SERVICES

Tag No.: B0142

Based on record review and staff interviews the facility failed to deploy psychiatrists to ensure psychiatric assessments were completed for two (2) of two (2) added patients (N1 and N2) admitted after hours. Specifically, the facility failed to provide 24-hour psychiatric coverage when the facility admits acutely and unstable mentally ill patients without a qualified psychiatrist assessment to provide appropriated psychotropic medications, observations and monitoring of patient's condition. This failure delays the treatment of acutely mentally ill patients with psychotropic medications and potentially dangerous behaviors without being properly medicated with antipsychotic or other psychiatric medications.

Findings include:

A. Record Review

1. Patient N1 was admitted on 11/2/17 at 3:30 p.m. for "Psychosis NOS and danger to self." The Root Cause Analysis (undated) stated, "Client was brought in by [spouse] to urgent care clinic for psychiatric evaluation due to increasingly unpredictable behavior. Client stated hearing voices telling [him\her] to harm [himself/herself] and [spouse] reported client was found with a knife attempting to [self-mutilate his/her genitals]." There was no psychiatric assessment completed prior to patient taken by police for allegations of murder the evening of 11/2/17. There was not a progress note or discharge summary documenting the time of discharge to police. This failure delays the treatment of acute symptoms with psychotropic medication and assessment of patient condition by a qualified psychiatrist.

2. Patient N2 was admitted on 11/2/17 at 4:00 p.m. for Unspecified Mood Disorder and danger to self." The Root Cause Analysis (undated) stated "[S/he] expressed feeling depressed, felt like hurting [himself/herself] with plans to stab [himself/herself] with pencils." There was no psychiatric assessment completed prior to patient transferred to another facility on 11/3/17 at 2:30 p.m. This failure delays the treatment of acute symptoms with psychotropic medication and assessment of patient condition by a qualified psychiatrist.

B. Document Review

The CEO provided to the surveyors the Board of Directors Meeting minutes dated November 17, 2017. The minutes stated: "The Board suggested: there needs to be a psychiatrist present. Need to have someone there that can adjust the medication immediately."

C. Staff Interview

On 8/1/18 at 10:15 a.m., the Medical Director agreed the psychiatric assessments were not completed and that the facility does not have psychiatrists on duty after hours.

MONITOR/EVALUATE QUALITY/APPROPRIATENESS OF SERVICES

Tag No.: B0144

Based on record review and interview, the Medical Director failed to:

I. Ensure that: Psychiatric Evaluations:

A. Included an estimation of patients' memory with supporting clinical evidence for six (6) of eight (8) active sample patients This deficiency compromises the database from which diagnoses are determined and from which changes in response to treatment interventions may be measured. (Refer to B110)

II. Provide adequate treatment and monitoring for one (1) of three (3) discharged patients (N1) who subsequently assaulted and murdered his/her roommate (E1). In addition, the facility failed to ensure that an adequate root cause analysis and a prompt review by their Morbidity and Mortality Board of the circumstances surrounding this event were completed to implement corrective actions. Without taking appropriate and immediate actions to mitigate risks and prevent future recurrence of these unsafe practices, the health and safety of all newly admitted patients may be jeopardized. (Refer to B125)

III. Ensure the discharge summaries are completed in a timely manner and signed by the physician within 14 days of discharge for three (3) of five (5) discharged patients (D1, D3, and D4) and for (3) of (3) added patients to review summaries (N1, N2, and E1). This deficiency results in a failure to communicate in a timely manner final diagnosis, current medications, the course of treatment, a summary of relevant labs and testing, anticipated problems and discharge plan with outpatient providers. (Refer to B133)

IV. Ensure adequate deployment of psychiatrists so that psychiatric assessments were completed for two (2) of two (2) added patients (N1 and N2) admitted after hours. Specifically, the facility failed to provide 24-hour psychiatric coverage when the facility admits acutely and unstable mentally ill patients without a qualified psychiatrist assessment to provide appropriated psychotropic medications, observations and monitoring of patient's condition. This failure delays the treatment of acutely mentally ill patients with psychotropic medications and potentially dangerous behaviors without being properly medicated with antipsychotic or other psychiatric medications. (Refer to B142)

PARTICIPATES IN FORMULATION OF TREATMENT PLANS

Tag No.: B0148

Based on document review and interview, the Director of Nursing failed to ensure that Patient N1 was monitored according to policy and that monitoring documents were consistent with the policy. This deficiency resulted in the patient being monitored inappropriately and potentially compromising his/her safety. (Refer to B125)

SOCIAL SERVICES

Tag No.: B0152

The Director of Social Work failed to ensure the quality and appropriateness of services provided by the social work staff. Specifically, the Director failed to assure that the Psychosocial Assessments included the anticipated social work roles in treatment for eight (8) of eight (8) (1, 2, 3, 4, 5, 6, 7, and 8) active sample patients. This failure results in a lack of professional social work information in treatment planning. (Refer to B108)